Unknown

Dataset Information

0

Development of a reverse transcription loop-mediated isothermal amplification method for the rapid detection of subtype H7N9 avian influenza virus.


ABSTRACT: A novel influenza A (H7N9) virus has emerged in China. To rapidly detect this virus from clinical samples, we developed a reverse transcription loop-mediated isothermal amplification (RT-LAMP) method for the detection of the H7N9 virus. The minimum detection limit of the RT-LAMP assay was 0.01 PFU H7N9 virus, making this method 100-fold more sensitive to the detection of the H7N9 virus than conventional RT-PCR. The H7N9 virus RT-LAMP assays can efficiently detect different sources of H7N9 influenza virus RNA (from chickens, pigeons, the environment, and humans). No cross-reactive amplification with the RNA of other subtype influenza viruses or of other avian respiratory viruses was observed. The assays can effectively detect H7N9 influenza virus RNA in drinking water, soil, cloacal swab, and tracheal swab samples that were collected from live poultry markets, as well as human H7N9 virus, in less than 30 min. These results suggest that the H7N9 virus RT-LAMP assays were efficient, practical, and rapid diagnostic methods for the epidemiological surveillance and diagnosis of influenza A (H7N9) virus from different resource samples.

SUBMITTER: Bao H 

PROVIDER: S-EPMC3933526 | biostudies-literature | 2014

REPOSITORIES: biostudies-literature

altmetric image

Publications

Development of a reverse transcription loop-mediated isothermal amplification method for the rapid detection of subtype H7N9 avian influenza virus.

Bao Hongmei H   Zhao Yuhui Y   Wang Yunhe Y   Xu Xiaolong X   Shi Jianzhong J   Zeng Xianying X   Wang Xiurong X   Chen Hualan H  

BioMed research international 20140206


A novel influenza A (H7N9) virus has emerged in China. To rapidly detect this virus from clinical samples, we developed a reverse transcription loop-mediated isothermal amplification (RT-LAMP) method for the detection of the H7N9 virus. The minimum detection limit of the RT-LAMP assay was 0.01 PFU H7N9 virus, making this method 100-fold more sensitive to the detection of the H7N9 virus than conventional RT-PCR. The H7N9 virus RT-LAMP assays can efficiently detect different sources of H7N9 influe  ...[more]

Similar Datasets

| S-EPMC3889764 | biostudies-literature
| S-EPMC4234856 | biostudies-literature
| S-EPMC4574065 | biostudies-literature
| S-EPMC3154870 | biostudies-literature
| S-EPMC4652103 | biostudies-literature
| S-EPMC7100760 | biostudies-literature
| S-EPMC7808867 | biostudies-literature
| S-EPMC6113474 | biostudies-literature
| S-EPMC7112856 | biostudies-literature
| S-EPMC7216271 | biostudies-literature