Unknown

Dataset Information

0

Effect of cardiac resynchronization therapy with implantable cardioverter defibrillator versus cardiac resynchronization therapy with pacemaker on mortality in heart failure patients: results of a high-volume, single-centre experience.


ABSTRACT:

Aims

There are limited and contradictory data on the effects of CRT with implantable cardioverter defibrillator (CRT-D) on mortality as compared with CRT with pacemaker (CRT-P).

Methods and results

We evaluated the long-term outcome of patients implanted with a CRT-D or CRT-P device in our high-volume single-centre experience. Data on all-cause mortality were derived from clinic visits and the Hungarian National Healthcare Fund Death Registry. Kaplan-Meier survival analyses and multivariate Cox regression models were used to evaluate all-cause mortality in patients with CRT-D vs. CRT-P, stratified by the aetiology of cardiomyopathy. From 2000 to 2011, 1122 CRT devices, 693 CRT-P (LVEF 28.2?±?7.4%) and 429 CRT-D (LVEF 27.6?±?6.4%), were implanted at our centre. During the median follow-up of 28 months, 379 patients died from any cause, 250 patients (36%) with an implanted CRT-P and 129 patients (30%) with an implanted CRT-D. There was no evidence of mortality benefit in patients implanted with a CRT-D compared with a CRT-P in the total cohort [hazard ratio (HR) 0.98, 95% confidence interval (CI) 0.73-1.32, P?=?0.884]. In patients with ischaemic cardiomyopathy, CRT-D treatment was associated with a significant 30% risk reduction in all-cause mortality compared with an implanted CRT-P (HR 0.70, 95% CI 0.51-0.97, P?=?0.03). In non-ischaemic patients, there was no mortality benefit of CRT-D over CRT-P (HR 0.98, 95% CI 0.73-1.32, P?=?0.894, interaction P-value?=?0.15).

Conclusions

In heart failure patients with ischaemic cardiomyopathy, CRT-D was associated with a mortality benefit compared with CRT-P, but no benefit of CRT-D over CRT-P in mortality was observed in non-ischaemic cardiomyopathy.

SUBMITTER: Kutyifa V 

PROVIDER: S-EPMC4309510 | biostudies-literature | 2014 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Effect of cardiac resynchronization therapy with implantable cardioverter defibrillator versus cardiac resynchronization therapy with pacemaker on mortality in heart failure patients: results of a high-volume, single-centre experience.

Kutyifa Valentina V   Geller Laszlo L   Bogyi Peter P   Zima Endre E   Aktas Mehmet K MK   Ozcan Emin Evren EE   Becker David D   Nagy Vivien Klaudia VK   Kosztin Annamaria A   Szilagyi Szabolcs S   Merkely Bela B  

European journal of heart failure 20141107 12


<h4>Aims</h4>There are limited and contradictory data on the effects of CRT with implantable cardioverter defibrillator (CRT-D) on mortality as compared with CRT with pacemaker (CRT-P).<h4>Methods and results</h4>We evaluated the long-term outcome of patients implanted with a CRT-D or CRT-P device in our high-volume single-centre experience. Data on all-cause mortality were derived from clinic visits and the Hungarian National Healthcare Fund Death Registry. Kaplan-Meier survival analyses and mu  ...[more]

Similar Datasets

| S-EPMC7011834 | biostudies-literature
| S-EPMC5814986 | biostudies-literature
| S-EPMC5259807 | biostudies-other
| S-EPMC7707981 | biostudies-literature
| S-EPMC5837710 | biostudies-literature
| S-EPMC4845241 | biostudies-literature
| S-EPMC6688862 | biostudies-literature
| S-EPMC8174382 | biostudies-literature
| S-EPMC5329118 | biostudies-literature
| S-EPMC4522701 | biostudies-literature