Unknown

Dataset Information

0

Association Between Subcutaneous Implantable Cardioverter Defibrillator Preimplantation Screening and the Response to Cardiac Resynchronization Therapy.


ABSTRACT: Background and objectives: Preimplantation QRS-T morphology screening (TMS) is a composite tool for selecting subcutaneous implantable cardioverter defibrillator (S-ICD) candidates. However, its role in predicting the patient's response to cardiac resynchronization therapy (CRT) is uncertain.

Methods: A total of 55 consecutive de novo CRT candidates were enrolled between January 2016 and March 2017. Electrocardiogram (ECG) and TMS were performed before and soon after implantation. The ECG parameters were recorded, including QRS duration and morphology (such as ?QRS_Index, QTc during biventricular pacing mode [BiV pacing QTc], and QRS/T ratio during biventricular pacing mode [BiV pacing QRS/T ratio]). TMS monitored three sensory vectors of the S-ICD. Six months after implantation, the responses to CRT were evaluated.

Results: Thirty-nine patients (70.9%) passed the TMS during biventricular pacing mode. At the six-month follow-up, the number of responders and super-responders was significantly higher in the passing group than in the non-passing group (responders: 31/39 [79.5%] vs. 5/16 [31.3%], p<0.001; super-responders: 9/39 [23.1%] vs. 1/16 [6.3%], p=0.020). The super-response rate was higher among patients who passed all three vectors than among those who passed 1 or 2 vectors (3 vs. 2 vectors, p=0.018; 3 vs. 1 vector, p=0.003). A smaller left atrial diameter, vectors that passed TMS during biventricular pacing mode, and larger ?QRS_Index values were independently associated with good CRT response.

Conclusions: Our study demonstrated that patients on CRT who pass the TMS during biventricular pacing mode are more likely to respond and super-respond to CRT.

SUBMITTER: Jing R 

PROVIDER: S-EPMC7707981 | biostudies-literature | 2020 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Association Between Subcutaneous Implantable Cardioverter Defibrillator Preimplantation Screening and the Response to Cardiac Resynchronization Therapy.

Jing Ran R   Jin Han H   Hua Wei W   Yang Shengwen S   Hu Yiran Y   Zhang Shu S  

Korean circulation journal 20201007 12


<h4>Background and objectives</h4>Preimplantation QRS-T morphology screening (TMS) is a composite tool for selecting subcutaneous implantable cardioverter defibrillator (S-ICD) candidates. However, its role in predicting the patient's response to cardiac resynchronization therapy (CRT) is uncertain.<h4>Methods</h4>A total of 55 consecutive de novo CRT candidates were enrolled between January 2016 and March 2017. Electrocardiogram (ECG) and TMS were performed before and soon after implantation. T  ...[more]

Similar Datasets

| S-EPMC7011834 | biostudies-literature
| S-EPMC5814986 | biostudies-literature
| S-EPMC5259807 | biostudies-literature
| S-EPMC5837710 | biostudies-literature
| S-EPMC4845241 | biostudies-literature
| S-EPMC6688862 | biostudies-literature
| S-EPMC7734049 | biostudies-literature
| S-EPMC7197388 | biostudies-literature
| S-EPMC4309510 | biostudies-literature