Unknown

Dataset Information

0

Real-time measurement of biomagnetic vector fields in functional syncytium using amorphous metal.


ABSTRACT: Magnetic field detection of biological electric activities would provide a non-invasive and aseptic estimate of the functional state of cellular organization, namely a syncytium constructed with cell-to-cell electric coupling. In this study, we investigated the properties of biomagnetic waves which occur spontaneously in gut musculature as a typical functional syncytium, by applying an amorphous metal-based gradio-magneto sensor operated at ambient temperature without a magnetic shield. The performance of differentiation was improved by using a single amorphous wire with a pair of transducer coils. Biomagnetic waves of up to several nT were recorded ~1 mm below the sample in a real-time manner. Tetraethyl ammonium (TEA) facilitated magnetic waves reflected electric activity in smooth muscle. The direction of magnetic waves altered depending on the relative angle of the muscle layer and magneto sensor, indicating the existence of propagating intercellular currents. The magnitude of magnetic waves rapidly decreased to ~30% by the initial and subsequent 1 mm separations between sample and sensor. The large distance effect was attributed to the feature of bioelectric circuits constructed by two reverse currents separated by a small distance. This study provides a method for detecting characteristic features of biomagnetic fields arising from a syncytial current.

SUBMITTER: Nakayama S 

PROVIDER: S-EPMC4351545 | biostudies-literature | 2015 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Real-time measurement of biomagnetic vector fields in functional syncytium using amorphous metal.

Nakayama Shinsuke S   Uchiyama Tusyoshi T  

Scientific reports 20150306


Magnetic field detection of biological electric activities would provide a non-invasive and aseptic estimate of the functional state of cellular organization, namely a syncytium constructed with cell-to-cell electric coupling. In this study, we investigated the properties of biomagnetic waves which occur spontaneously in gut musculature as a typical functional syncytium, by applying an amorphous metal-based gradio-magneto sensor operated at ambient temperature without a magnetic shield. The perf  ...[more]

Similar Datasets

| S-EPMC7809347 | biostudies-literature
| S-EPMC7288304 | biostudies-literature
| S-EPMC419623 | biostudies-literature
| S-EPMC4055617 | biostudies-literature
| S-EPMC6750642 | biostudies-literature
| S-EPMC8178804 | biostudies-literature
| S-EPMC6983720 | biostudies-literature
| S-EPMC7427561 | biostudies-literature