Unknown

Dataset Information

0

Real-time measurement of diffusion exchange rate in biological tissue.


ABSTRACT: Diffusion exchange spectroscopy (DEXSY) provides a means to isolate the signal attenuation associated with exchange from other sources of signal loss. With the total diffusion weighting b1+b2=bs held constant, DEXSY signals acquired with b1=0 or b2=0 have no exchange weighting, while a DEXSY signal acquired with b1=b2 has maximal exchange weighting. The exchange rate can be estimated by fitting a diffusion exchange model to signals acquired with variable mixing times. Conventionally, acquired signals are normalized by a signal with b1=0 and b2=0 to remove the decay due to spin-lattice relaxation. Instead, division by a signal with equal bs but b1=0 or b2=0 reduces spin-lattice relaxation weighting of the apparent exchange rate (AXR). Furthermore, apparent diffusion-weighted R1 relaxation rates can be estimated from non-exchange-weighted DEXSY signals. Estimated R1 values are utilized to remove signal decay due to spin-lattice relaxation from exchange-weighted signals, permitting a more precise estimate of AXR with less data. Data reduction methods are proposed and tested with regards to statistical accuracy and precision of AXR estimates on simulated and experimental data. Simulations show that the methods are capable of accurately measuring the ground-truth exchange rate. The methods remain accurate even when the assumption that DEXSY signals attenuate with b is violated, as occurs for restricted diffusion. Experimental data was collected from fixed neonatal mouse spinal cord samples at 25 and 7°C using the strong static magnetic field gradient produced by a single-sided permanent magnet (i.e., an NMR MOUSE). The most rapid method for exchange measurements requires only five data points (an 80 s experiment as implemented) and achieves a similar level of accuracy and precision to the baseline method using 44 data points. This represents a significant improvement in acquisition speed, overcoming a barrier which has limited the use of DEXSY on living specimen.

SUBMITTER: Williamson NH 

PROVIDER: S-EPMC7427561 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC2633595 | biostudies-literature
| S-EPMC5866507 | biostudies-literature
| S-EPMC7288304 | biostudies-literature
| S-EPMC419623 | biostudies-literature
| S-EPMC4055617 | biostudies-literature
| S-EPMC4976700 | biostudies-literature