Unknown

Dataset Information

0

Safety Evaluation of Hemoglobin-Albumin Cluster "HemoAct" as a Red Blood Cell Substitute.


ABSTRACT: A hemoglobin (Hb) wrapped covalently by human serum albumins (HSAs), a core-shell structured hemoglobin-albumin cluster designated as "HemoAct", is an O2-carrier designed for use as a red blood cell (RBC) substitute. This report describes the blood compatibility, hemodynamic response, and pharmacokinetic properties of HemoAct, and then explains its preclinical safety. Viscosity and blood cell counting measurements revealed that HemoAct has good compatibility with whole blood. Intravenous administration of HemoAct into anesthetized rats elicited no unfavorable increase in systemic blood pressure by vasoconstriction. The half-life of (125)I-labeled HemoAct in circulating blood is markedly longer than that of HSA. Serum biochemical tests conducted 7 days after HemoAct infusion yielded equivalent values to those observed in the control group with HSA. Histopathologic inspections of the vital organs revealed no marked abnormality in their tissues. All results indicate that HemoAct has sufficient preclinical safety as an alternative material for RBC transfusion.

SUBMITTER: Haruki R 

PROVIDER: S-EPMC4518235 | biostudies-literature | 2015 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Safety Evaluation of Hemoglobin-Albumin Cluster "HemoAct" as a Red Blood Cell Substitute.

Haruki Risa R   Kimura Takuya T   Iwasaki Hitomi H   Yamada Kana K   Kamiyama Ikuo I   Kohno Mitsutomo M   Taguchi Kazuaki K   Nagao Saori S   Maruyama Toru T   Otagiri Masaki M   Komatsu Teruyuki T  

Scientific reports 20150729


A hemoglobin (Hb) wrapped covalently by human serum albumins (HSAs), a core-shell structured hemoglobin-albumin cluster designated as "HemoAct", is an O2-carrier designed for use as a red blood cell (RBC) substitute. This report describes the blood compatibility, hemodynamic response, and pharmacokinetic properties of HemoAct, and then explains its preclinical safety. Viscosity and blood cell counting measurements revealed that HemoAct has good compatibility with whole blood. Intravenous adminis  ...[more]

Similar Datasets

| S-EPMC6017026 | biostudies-literature
| S-EPMC6976897 | biostudies-literature
| S-EPMC2700065 | biostudies-literature
| S-EPMC6744332 | biostudies-literature
| S-EPMC3891836 | biostudies-other
| S-EPMC5714656 | biostudies-literature
| S-EPMC5078773 | biostudies-literature
| S-EPMC4195732 | biostudies-literature
| S-EPMC1567689 | biostudies-literature
| EMPIAR-10848 | biostudies-other