Unknown

Dataset Information

0

Red blood cell thickness is evolutionarily constrained by slow, hemoglobin-restricted diffusion in cytoplasm.


ABSTRACT: During capillary transit, red blood cells (RBCs) must exchange large quantities of CO2 and O2 in typically less than one second, but the degree to which this is rate-limited by diffusion through cytoplasm is not known. Gas diffusivity is intuitively assumed to be fast and this would imply that the intracellular path-length, defined by RBC shape, is not a factor that could meaningfully compromise physiology. Here, we evaluated CO2 diffusivity (DCO2) in RBCs and related our results to cell shape. DCO2 inside RBCs was determined by fluorescence imaging of [H+] dynamics in cells under superfusion. This method is based on the principle that H+ diffusion is facilitated by CO2/HCO3- buffer and thus provides a read-out of DCO2. By imaging the spread of H+ ions from a photochemically-activated source (6-nitroveratraldehyde), DCO2 in human RBCs was calculated to be only 5% of the rate in water. Measurements on RBCs containing different hemoglobin concentrations demonstrated a halving of DCO2 with every 75?g/L increase in mean corpuscular hemoglobin concentration (MCHC). Thus, to compensate for highly-restricted cytoplasmic diffusion, RBC thickness must be reduced as appropriate for its MCHC. This can explain the inverse relationship between MCHC and RBC thickness determined from >250 animal species.

SUBMITTER: Richardson SL 

PROVIDER: S-EPMC5078773 | biostudies-literature | 2016 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Red blood cell thickness is evolutionarily constrained by slow, hemoglobin-restricted diffusion in cytoplasm.

Richardson Sarah L SL   Swietach Pawel P  

Scientific reports 20161025


During capillary transit, red blood cells (RBCs) must exchange large quantities of CO<sub>2</sub> and O<sub>2</sub> in typically less than one second, but the degree to which this is rate-limited by diffusion through cytoplasm is not known. Gas diffusivity is intuitively assumed to be fast and this would imply that the intracellular path-length, defined by RBC shape, is not a factor that could meaningfully compromise physiology. Here, we evaluated CO<sub>2</sub> diffusivity (D<sub>CO2</sub>) in  ...[more]

Similar Datasets

| S-EPMC5585185 | biostudies-literature
| S-EPMC7531998 | biostudies-literature
| S-EPMC1567689 | biostudies-literature
| S-EPMC6976897 | biostudies-literature
| S-EPMC2586580 | biostudies-literature
| S-EPMC2700065 | biostudies-literature
| S-EPMC7379282 | biostudies-literature
| S-EPMC4393193 | biostudies-literature
| S-EPMC4518235 | biostudies-literature
| S-EPMC5714656 | biostudies-literature