Integrated micro-optofluidic platform for real-time detection of airborne microorganisms.


ABSTRACT: We demonstrate an integrated micro-optofluidic platform for real-time, continuous detection and quantification of airborne microorganisms. Measurements of the fluorescence and light scattering from single particles in a microfluidic channel are used to determine the total particle number concentration and the microorganism number concentration in real-time. The system performance is examined by evaluating standard particle measurements with various sample flow rates and the ratios of fluorescent to non-fluorescent particles. To apply this method to real-time detection of airborne microorganisms, airborne Escherichia coli, Bacillus subtilis, and Staphylococcus epidermidis cells were introduced into the micro-optofluidic platform via bioaerosol generation, and a liquid-type particle collection setup was used. We demonstrate successful discrimination of SYTO82-dyed fluorescent bacterial cells from other residue particles in a continuous and real-time manner. In comparison with traditional microscopy cell counting and colony culture methods, this micro-optofluidic platform is not only more accurate in terms of the detection efficiency for airborne microorganisms but it also provides additional information on the total particle number concentration.

SUBMITTER: Choi J 

PROVIDER: S-EPMC4629162 | biostudies-literature | 2015

REPOSITORIES: biostudies-literature

altmetric image

Publications

Integrated micro-optofluidic platform for real-time detection of airborne microorganisms.

Choi Jeongan J   Kang Miran M   Jung Jae Hee JH  

Scientific reports 20151102


We demonstrate an integrated micro-optofluidic platform for real-time, continuous detection and quantification of airborne microorganisms. Measurements of the fluorescence and light scattering from single particles in a microfluidic channel are used to determine the total particle number concentration and the microorganism number concentration in real-time. The system performance is examined by evaluating standard particle measurements with various sample flow rates and the ratios of fluorescent  ...[more]

Similar Datasets

| S-EPMC8658630 | biostudies-literature
| S-EPMC3834602 | biostudies-literature
| S-EPMC2906424 | biostudies-literature
| S-EPMC2682748 | biostudies-other
| S-EPMC3573335 | biostudies-literature
| S-EPMC7478360 | biostudies-literature
| S-EPMC8789398 | biostudies-literature
| S-EPMC6191610 | biostudies-literature
| S-EPMC7333463 | biostudies-literature
| S-EPMC4939750 | biostudies-literature