Unknown

Dataset Information

0

Single domain antibody coated gold nanoparticles as enhancer for Clostridium difficile toxin detection by electrochemical impedance immunosensors.


ABSTRACT: This work presents a sandwich-type electrochemical impedance immunosensor for detecting Clostridium difficile toxin A (TcdA) and toxin B (TcdB). Single domain antibody conjugated gold nanoparticles were applied to amplify the detection signal. Gold nanoparticles (Au NPs) were characterized by transmission electron microscopy and UV–vis spectra. The electron transfer resistance (Ret) of the working electrode surface was used as a parameter in the measurement of the biosensor. With the increase of the concentration of toxins from 1 pg/mL to 100 pg/mL, a linear relationship was observed between the relative electron transfer resistance and toxin concentration. In addition, the detection signal was enhanced due to the amplification effect. The limit of detection for TcdA and TcdB was found to be 0.61 pg/mL and 0.60 pg/mL respectively at a signal-to-noise ratio of 3 (S/N = 3). This method is simple, fast and ultrasensitive, thus possesses a great potential for clinical applications in the future.

SUBMITTER: Zhu Z 

PROVIDER: S-EPMC4706752 | biostudies-literature | 2015 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Single domain antibody coated gold nanoparticles as enhancer for Clostridium difficile toxin detection by electrochemical impedance immunosensors.

Zhu Zanzan Z   Shi Lianfa L   Feng Hanping H   Zhou H Susan HS  

Bioelectrochemistry (Amsterdam, Netherlands) 20150201


This work presents a sandwich-type electrochemical impedance immunosensor for detecting Clostridium difficile toxin A (TcdA) and toxin B (TcdB). Single domain antibody conjugated gold nanoparticles were applied to amplify the detection signal. Gold nanoparticles (Au NPs) were characterized by transmission electron microscopy and UV–vis spectra. The electron transfer resistance (Ret) of the working electrode surface was used as a parameter in the measurement of the biosensor. With the increase of  ...[more]

Similar Datasets

| S-EPMC6798460 | biostudies-literature
2022-09-01 | GSE197944 | GEO
| S-EPMC4976693 | biostudies-literature
| S-EPMC2905592 | biostudies-literature
| S-EPMC5648702 | biostudies-literature
| S-EPMC2786741 | biostudies-literature
| S-EPMC6749185 | biostudies-literature
| S-EPMC87004 | biostudies-literature
| S-EPMC2679968 | biostudies-literature
| S-EPMC3318759 | biostudies-literature