Unknown

Dataset Information

0

Prospective Study for Comparison of Endoscopic Ultrasound-Guided Tissue Acquisition Using 25- and 22-Gauge Core Biopsy Needles in Solid Pancreatic Masses.


ABSTRACT: BACKGROUND AND AIMS:Although thicker needles theoretically allow more tissue to be collected, their decreased flexibility can cause mechanical damage to the endoscope, technical failure, and sample blood contamination. The effects of needle gauge on diagnostic outcomes of endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) of pancreatic mass lesions remain unknown. This study compared procurement rates of histologic cores obtained from EUS-FNB of pancreatic masses using 25- and 22-gauge core biopsy needles. PATIENTS AND METHODS:From March 2014 to July 2014, 66 patients with solid pancreatic mass underwent EUS-FNB with both 25- and 22-gauge core biopsy needles. Among them, 10 patients were excluded and thus 56 patients were eligible for the analyses. Needle sequences were randomly assigned, and two passes were made with each needle, consisting of 10 uniform to-and-fro movements on each pass with 10 mL syringe suction. A pathologist blinded to needle sequence evaluated specimens for the presence of histologic core. RESULTS:The mean patient age was 65.8 ± 9.5 years (range, 44-89 years); 35 patients (62.5%) were men. The mean pancreatic mass size was 35.3 ± 17.1 mm (range 14-122.3 mm). Twenty-eight patients (50%) had tumors at the pancreas head or uncinate process. There were no significant differences in procurement rates of histologic cores between 25-gauge (49/56, 87.5%) and 22-gauge (46/56, 82.1%, P = 0.581) needles or diagnostic accuracy using only histologic cores (98% and 95%). There were no technical failures or procedure-related adverse events. CONCLUSIONS:The 25-gauge core biopsy needle could offer acceptable and comparable outcomes regarding diagnostic performance including histologic core procurement rates compared to the 22-gauge core biopsy needle, although the differences were not statistically significant. TRIAL REGISTRATION:ClinicalTrials.gov NCT01795066.

SUBMITTER: Park SW 

PROVIDER: S-EPMC4858215 | biostudies-literature | 2016

REPOSITORIES: biostudies-literature

altmetric image

Publications

Prospective Study for Comparison of Endoscopic Ultrasound-Guided Tissue Acquisition Using 25- and 22-Gauge Core Biopsy Needles in Solid Pancreatic Masses.

Park Se Woo SW   Chung Moon Jae MJ   Lee Sang Hoon SH   Lee Hee Seung HS   Lee Hyun Jik HJ   Park Jeong Yup JY   Park Seung Woo SW   Song Si Young SY   Kim Hoguen H   Chung Jae Bock JB   Bang Seungmin S  

PloS one 20160505 5


<h4>Background and aims</h4>Although thicker needles theoretically allow more tissue to be collected, their decreased flexibility can cause mechanical damage to the endoscope, technical failure, and sample blood contamination. The effects of needle gauge on diagnostic outcomes of endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) of pancreatic mass lesions remain unknown. This study compared procurement rates of histologic cores obtained from EUS-FNB of pancreatic masses using 25- and 22-  ...[more]

Similar Datasets

| S-EPMC5075557 | biostudies-literature
| S-EPMC6257123 | biostudies-literature
| S-EPMC5625867 | biostudies-other
| S-EPMC7184661 | biostudies-literature
| S-EPMC4148209 | biostudies-literature
| S-EPMC6773615 | biostudies-literature
| S-EPMC6327728 | biostudies-literature
| S-EPMC5348295 | biostudies-literature
| S-EPMC4612231 | biostudies-literature
| S-EPMC4486032 | biostudies-other