Visualization of pulmonary clearance mechanisms via noninvasive optical imaging validated by near-infrared flow cytometry.


ABSTRACT: In vivo optical imaging with near-infrared (NIR) probes is an established method of diagnostics in preclinical and clinical studies. However, the specificities of these probes are difficult to validate ex vivo due to the lack of NIR flow cytometry. To address this limitation, we modified a flow cytometer to include an additional NIR channel using a 752 nm laser line. The flow cytometry system was tested using NIR microspheres and cell lines labeled with a combination of visible range and NIR fluorescent dyes. The approach was verified in vivo in mice evaluated for immune response in lungs after intratracheal delivery of the NIR contrast agent. Flow cytometry of cells obtained from the lung bronchoalveolar lavage demonstrated that the NIR dye was taken up by pulmonary macrophages as early as 4-h post-injection. This combination of optical imaging with NIR flow cytometry extends the capability of imaging and enables complementation of in vivo imaging with cell-specific studies.

SUBMITTER: Zhou H 

PROVIDER: S-EPMC4860906 | biostudies-literature | 2015 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Visualization of pulmonary clearance mechanisms via noninvasive optical imaging validated by near-infrared flow cytometry.

Zhou Haiying H   Gunsten Sean P SP   Zhegalova Natalia G NG   Bloch Sharon S   Achilefu Samuel S   Christopher Holley J J   Schweppe Daniel D   Akers Walter W   Brody Steven L SL   Eades William C WC   Berezin Mikhail Y MY  

Cytometry. Part A : the journal of the International Society for Analytical Cytology 20150323 5


In vivo optical imaging with near-infrared (NIR) probes is an established method of diagnostics in preclinical and clinical studies. However, the specificities of these probes are difficult to validate ex vivo due to the lack of NIR flow cytometry. To address this limitation, we modified a flow cytometer to include an additional NIR channel using a 752 nm laser line. The flow cytometry system was tested using NIR microspheres and cell lines labeled with a combination of visible range and NIR flu  ...[more]

Similar Datasets

| S-EPMC3594514 | biostudies-literature
| S-EPMC6977010 | biostudies-literature
| S-EPMC3564022 | biostudies-literature
| S-EPMC7806866 | biostudies-literature
| S-EPMC3568187 | biostudies-literature
| S-EPMC4190570 | biostudies-literature
| S-EPMC5222978 | biostudies-literature
| S-EPMC5610617 | biostudies-literature
| S-EPMC4185369 | biostudies-literature