Novel ZnO:Al contacts to CdZnTe for X- and gamma-ray detectors.


ABSTRACT: CdZnTe (CZT) has made a significant impact as a material for room-temperature nuclear-radiation detectors due to its potential impact in applications related to nonproliferation, homeland security, medical imaging, and gamma-ray telescopes. In all such applications, common metals, such as gold, platinum and indium, have been used as electrodes for fabricating the detectors. Because of the large mismatch in the thermal-expansion coefficient between the metal contacts and CZT, the contacts can undergo stress and mechanical degradation, which is the main cause for device instability over the long term. Here, we report for the first time on our use of Al-doped ZnO as the preferred electrode for such detectors. The material was selected because of its better contact properties compared to those of the metals commonly used today. Comparisons were conducted for the detector properties using different contacts, and improvements in the performances of ZnO:Al-coated detectors are described in this paper. These studies show that Al:ZnO contacts to CZT radiation detectors offer the potential of becoming a transformative replacement for the common metallic contacts due to the dramatic improvements in the performance of detectors and improved long-term stability.

SUBMITTER: Roy UN 

PROVIDER: S-EPMC4877641 | biostudies-literature | 2016 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Novel ZnO:Al contacts to CdZnTe for X- and gamma-ray detectors.

Roy U N UN   Mundle R M RM   Camarda G S GS   Cui Y Y   Gul R R   Hossain A A   Yang G G   Pradhan A K AK   James R B RB  

Scientific reports 20160524


CdZnTe (CZT) has made a significant impact as a material for room-temperature nuclear-radiation detectors due to its potential impact in applications related to nonproliferation, homeland security, medical imaging, and gamma-ray telescopes. In all such applications, common metals, such as gold, platinum and indium, have been used as electrodes for fabricating the detectors. Because of the large mismatch in the thermal-expansion coefficient between the metal contacts and CZT, the contacts can und  ...[more]

Similar Datasets

| S-EPMC7426932 | biostudies-literature
| S-EPMC5529301 | biostudies-other
| S-EPMC7331028 | biostudies-literature
| S-EPMC10589347 | biostudies-literature
| S-EPMC8121847 | biostudies-literature
| S-EPMC8421435 | biostudies-literature
| S-EPMC8613224 | biostudies-literature
| S-EPMC9756221 | biostudies-literature
| S-EPMC6435812 | biostudies-literature
| S-EPMC7740104 | biostudies-literature