Unknown

Dataset Information

0

Determination of X-ray detection limit and applications in perovskite X-ray detectors.


ABSTRACT: X-ray detection limit and sensitivity are important figure of merits for perovskite X-ray detectors, but literatures lack a valid mathematic expression for determining the lower limit of detection for a perovskite X-ray detector. In this work, we present a thorough analysis and new method for X-ray detection limit determination based on a statistical model that correlates the dark current and the X-ray induced photocurrent with the detection limit. The detection limit can be calculated through the measurement of dark current and sensitivity with an easy-to-follow practice. Alternatively, the detection limit may also be obtained by the measurement of dark current and photocurrent when repeatedly lowering the X-ray dose rate. While the material quality is critical, we show that the device architecture and working mode also have a significant influence on the sensitivity and the detection limit. Our work establishes a fair comparison metrics for material and detector development.

SUBMITTER: Pan L 

PROVIDER: S-EPMC8421435 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC7740104 | biostudies-literature
| S-EPMC8613224 | biostudies-literature
| S-EPMC9756221 | biostudies-literature
| S-EPMC6435812 | biostudies-literature
| S-EPMC8365385 | biostudies-literature
| S-EPMC8442865 | biostudies-literature
| S-EPMC8405692 | biostudies-literature
| S-EPMC7676260 | biostudies-literature
| S-EPMC7547111 | biostudies-literature
| S-EPMC10003980 | biostudies-literature