Unknown

Dataset Information

0

Amide Proton Transfer Imaging of Diffuse Gliomas: Effect of Saturation Pulse Length in Parallel Transmission-Based Technique.


ABSTRACT: In this study, we evaluated the dependence of saturation pulse length on APT imaging of diffuse gliomas using a parallel transmission-based technique. Twenty-two patients with diffuse gliomas (9 low-grade gliomas, LGGs, and 13 high-grade gliomas, HGGs) were included in the study. APT imaging was conducted at 3T with a 2-channel parallel transmission scheme using three different saturation pulse lengths (0.5 s, 1.0 s, 2.0 s). The 2D fast spin-echo sequence was used for imaging. Z-spectrum was obtained at 25 frequency offsets from -6 to +6 ppm (step 0.5 ppm). A point-by-point B0 correction was performed with a B0 map. Magnetization transfer ratio (MTRasym) and ?MTRasym (contrast between tumor and normal white matter) at 3.5 ppm were compared among different saturation lengths. A significant increase in MTRasym (3.5 ppm) of HGG was found when the length of saturation pulse became longer (3.09 ± 0.54% at 0.5 s, 3.83 ± 0.67% at 1 s, 4.12 ± 0.97% at 2 s), but MTRasym (3.5 ppm) was not different among the saturation lengths in LGG. ?MTRasym (3.5 ppm) increased with the length of saturation pulse in both LGG (0.48 ± 0.56% at 0.5 s, 1.28 ± 0.56% at 1 s, 1.88 ± 0.56% at 2 s and HGG (1.72 ± 0.54% at 0.5 s, 2.90 ± 0.49% at 1 s, 3.83 ± 0.88% at 2 s). In both LGG and HGG, APT-weighted contrast was enhanced with the use of longer saturation pulses.

SUBMITTER: Togao O 

PROVIDER: S-EPMC4881971 | biostudies-literature | 2016

REPOSITORIES: biostudies-literature

altmetric image

Publications

Amide Proton Transfer Imaging of Diffuse Gliomas: Effect of Saturation Pulse Length in Parallel Transmission-Based Technique.

Togao Osamu O   Hiwatashi Akio A   Keupp Jochen J   Yamashita Koji K   Kikuchi Kazufumi K   Yoshiura Takashi T   Yoneyama Masami M   Kruiskamp Marijn J MJ   Sagiyama Koji K   Takahashi Masaya M   Honda Hiroshi H  

PloS one 20160526 5


In this study, we evaluated the dependence of saturation pulse length on APT imaging of diffuse gliomas using a parallel transmission-based technique. Twenty-two patients with diffuse gliomas (9 low-grade gliomas, LGGs, and 13 high-grade gliomas, HGGs) were included in the study. APT imaging was conducted at 3T with a 2-channel parallel transmission scheme using three different saturation pulse lengths (0.5 s, 1.0 s, 2.0 s). The 2D fast spin-echo sequence was used for imaging. Z-spectrum was obt  ...[more]

Similar Datasets

| S-EPMC5456413 | biostudies-literature
| S-EPMC9315051 | biostudies-literature
| S-EPMC5744877 | biostudies-literature
| S-EPMC5561497 | biostudies-literature
| S-EPMC4946988 | biostudies-literature
| S-EPMC6422734 | biostudies-literature
| S-EPMC7943598 | biostudies-literature
| S-EPMC5572540 | biostudies-literature
| S-EPMC7771875 | biostudies-literature
| S-EPMC10502874 | biostudies-literature