Impact of MR-Based Attenuation Correction on Neurologic PET Studies.


ABSTRACT: Hybrid PET and MR scanners have become a reality in recent years, with the benefits of reduced radiation exposure, reduction of imaging time, and potential advantages in quantification. Appropriate attenuation correction remains a challenge. Biases in PET activity measurements were demonstrated using the current MR-based attenuation-correction technique. We aimed to investigate the impact of using a standard MR-based attenuation correction technique on the clinical and research utility of a PET/MR hybrid scanner for amyloid imaging.Florbetapir scans were obtained for 40 participants on a hybrid scanner with simultaneous MR acquisition. PET images were reconstructed using both MR- and CT-derived attenuation maps. Quantitative analysis was performed for both datasets to assess the impact of MR-based attenuation correction to absolute PET activity measurements as well as target-to-reference ratio (SUVR). Clinical assessment was also performed by a nuclear medicine physician to determine amyloid status based on the criteria in the Food and Drug Administration prescribing information for florbetapir.MR-based attenuation correction led to underestimation of PET activity for most parts of the brain, with a small overestimation for deep brain regions. There was also an overestimation of SUVRs with cerebellar reference. SUVR measurements obtained from the 2 attenuation-correction methods were strongly correlated. Clinical assessment of amyloid status resulted in identical classification as positive or negative regardless of the attenuation-correction methods.MR-based attenuation correction causes biases in quantitative measurements. The biases may be accounted for by a linear model, although the spatial variation cannot be easily modeled. The quantitative differences, however, did not affect clinical assessment as positive or negative.

SUBMITTER: Su Y 

PROVIDER: S-EPMC4891225 | biostudies-literature | 2016 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Impact of MR-Based Attenuation Correction on Neurologic PET Studies.

Su Yi Y   Rubin Brian B BB   McConathy Jonathan J   Laforest Richard R   Qi Jing J   Sharma Akash A   Priatna Agus A   Benzinger Tammie L S TL  

Journal of nuclear medicine : official publication, Society of Nuclear Medicine 20160128 6


<h4>Unlabelled</h4>Hybrid PET and MR scanners have become a reality in recent years, with the benefits of reduced radiation exposure, reduction of imaging time, and potential advantages in quantification. Appropriate attenuation correction remains a challenge. Biases in PET activity measurements were demonstrated using the current MR-based attenuation-correction technique. We aimed to investigate the impact of using a standard MR-based attenuation correction technique on the clinical and researc  ...[more]

Similar Datasets

| S-EPMC3801218 | biostudies-literature
| S-EPMC9293017 | biostudies-literature
| S-EPMC4090355 | biostudies-other
| S-EPMC3477199 | biostudies-other
| S-EPMC5843521 | biostudies-literature
| S-EPMC6173790 | biostudies-literature
| S-EPMC6433217 | biostudies-literature
| S-EPMC7375929 | biostudies-literature
| S-EPMC6779234 | biostudies-literature
| S-EPMC5877454 | biostudies-literature