Rapid dual-echo ramped hybrid encoding MR-based attenuation correction (dRHE-MRAC) for PET/MR.


ABSTRACT: PURPOSE:In this study, we propose a rapid acquisition for MR-based attenuation correction (MRAC) in positron emission tomography (PET)/MR imaging, in which an ultrashort echo time (UTE) image and an out-of-phase echo image are obtained within a single rapid scan (35 s) at high spatial resolution (1?mm3 ), which allows accurate estimation of a pseudo CT image using 4-class tissue classification (discrete bone, discrete air, continuous fat, and continuous water). METHODS:In dual-echo ramped hybrid encoding (dRHE), a UTE echo is directly followed by a second out-of-phase echo, in which hybrid spatial encoding combining single-point imaging and 3-dimensional radial frequency encoding is used to improve the quality of both images. Two-point Dixon reconstruction is used to estimate fat- and water-separated images, and UTE images are used to estimate bone. Air and bone segmentation is improved by using multiple UTE images with an advanced hybrid-encoding scheme that allows reconstruction of multiple UTE images. To evaluate the proposed method, dRHE-MRAC PET/MR brain imaging was performed in 10 subjects. Dice coefficients and PET reconstruction errors relative to CT-based attenuation correction were compared with existing system MRAC approaches. RESULTS:In dRHE-MRAC, the Dice coefficients for soft tissue, air, and bone were respectively 0.95?±?0.01, 0.62?±?0.06, and 0.78?±?0.05, which was a significantly improved result compared with existing approaches. In most brain regions, dRHE-MRAC showed significantly reduced PET error (less than 1%) with P values less than 0.05. CONCLUSIONS:Dual-echo ramped hybrid encoding enables rapid and robust imaging for MRAC with a very rapid acquisition. Magn Reson Med 79:2912-2922, 2018. © 2017 International Society for Magnetic Resonance in Medicine.

SUBMITTER: Jang H 

PROVIDER: S-EPMC5843521 | biostudies-literature | 2018 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Rapid dual-echo ramped hybrid encoding MR-based attenuation correction (dRHE-MRAC) for PET/MR.

Jang Hyungseok H   Liu Fang F   Bradshaw Tyler T   McMillan Alan B AB  

Magnetic resonance in medicine 20171002 6


<h4>Purpose</h4>In this study, we propose a rapid acquisition for MR-based attenuation correction (MRAC) in positron emission tomography (PET)/MR imaging, in which an ultrashort echo time (UTE) image and an out-of-phase echo image are obtained within a single rapid scan (35 s) at high spatial resolution (1 mm<sup>3</sup> ), which allows accurate estimation of a pseudo CT image using 4-class tissue classification (discrete bone, discrete air, continuous fat, and continuous water).<h4>Methods</h4>  ...[more]

Similar Datasets

| S-EPMC7375929 | biostudies-literature
| S-EPMC6433217 | biostudies-literature
| S-EPMC6196145 | biostudies-literature
| S-EPMC4090355 | biostudies-other
| S-EPMC4891225 | biostudies-literature
| S-EPMC5877454 | biostudies-literature
| S-EPMC7190435 | biostudies-literature
| S-EPMC3477199 | biostudies-other
| S-EPMC3869851 | biostudies-other
| S-EPMC9293017 | biostudies-literature