Unknown

Dataset Information

0

Catch and release: integrated system for multiplexed detection of bacteria.


ABSTRACT: An integrated system with automated immunomagnetic separation and processing of fluidic samples was demonstrated for multiplexed optical detection of bacterial targets. Mixtures of target-specific magnetic bead sets were processed in the NRL MagTrap with the aid of rotating magnet arrays that entrapped and moved the beads within the channel during reagent processing. Processing was performed in buffer and human serum matrixes with 10-fold dilutions in the range of 10(2)-10(6) cells/mL of target bacteria. Reversal of magnets' rotation post-processing released the beads back into the flow and moved them into the microflow cytometer for optical interrogation. Identification of the beads and the detection of PE fluorescence were performed simultaneously for multiplexed detection. Multiplexing was performed with specifically targeted bead sets to detect E. coli 0157.H7, Salmonella Common Structural Antigen, Listeria sp., and Shigella sp., dose-response curves were obtained, and limits of detection were calculated for each target in the buffer and clinical matrix. Additional tests demonstrated the potential for using the MagTrap to concentrate target from larger volumes of sample prior to the addition of assay reagents.

SUBMITTER: Verbarg J 

PROVIDER: S-EPMC5012220 | biostudies-literature | 2013 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Catch and release: integrated system for multiplexed detection of bacteria.

Verbarg Jasenka J   Plath William D WD   Shriver-Lake Lisa C LC   Howell Peter B PB   Erickson Jeffrey S JS   Golden Joel P JP   Ligler Frances S FS  

Analytical chemistry 20130430 10


An integrated system with automated immunomagnetic separation and processing of fluidic samples was demonstrated for multiplexed optical detection of bacterial targets. Mixtures of target-specific magnetic bead sets were processed in the NRL MagTrap with the aid of rotating magnet arrays that entrapped and moved the beads within the channel during reagent processing. Processing was performed in buffer and human serum matrixes with 10-fold dilutions in the range of 10(2)-10(6) cells/mL of target  ...[more]

Similar Datasets

| S-BSST1044 | biostudies-other
| S-EPMC2772421 | biostudies-literature
| S-EPMC3631427 | biostudies-literature
| S-EPMC7506896 | biostudies-literature
| S-EPMC2747802 | biostudies-literature
| S-EPMC5070463 | biostudies-literature
| S-EPMC6050343 | biostudies-literature
| S-EPMC8105640 | biostudies-literature
| S-EPMC4243214 | biostudies-literature
| S-EPMC1783141 | biostudies-literature