Comparative Study of Voxel-Based Epileptic Foci Localization Accuracy between Statistical Parametric Mapping and Three-dimensional Stereotactic Surface Projection.


ABSTRACT:

Introduction

Fluorine-18-fluorodeoxyglucose positron-emission tomography (18F-FDG-PET) is widely used to help localize the hypometabolic epileptogenic focus for presurgical evaluation of drug-refractory epilepsy patients. Two voxel-based brain mapping methods to interpret 18F-FDG-PET, statistical parametric mapping (SPM) and three-dimensional stereotactic surface projection (3D-SSP), improve the detection rate of seizure foci. This study aimed to compare the consistency of epileptic focus detection between SPM and 3D-SSP for 18F-FDG-PET brain mapping analysis.

Methods

We retrospectively reviewed the clinical, electroecephalographic, and brain imaging results of 35 patients with refractory epilepsy. 18F-FDG-PET studies were revaluated by SPM, 3D-SSP, and visual assessment, and the results were compared to the magnetic resonance imaging (MRI) lesion location and to the presumed epileptogenic zone (PEZ) defined by video-electroencephalogram and other clinical data. A second consistency study compared PET analyses to histopathology and surgical outcomes in the 19 patients who underwent lesion resection surgery.

Results

Of the 35 patients, consistency with the PEZ was 29/35 for SPM, 25/35 for 3D-SSP, 14/35 for visual assessment, and 10/35 for MRI. Concordance rates with the PEZ were significantly higher for SPM and 3D-SSP than for MRI (P?P?P?>?0.05). A favorable Engel outcome (class I/II) was found in 16 of 19 cases (84%), and failure of seizure control was found in 3 of 19 patients (class III/IV).

Conclusion

Voxel-based 18F-FDG-PET brain mapping analysis using SPM or 3D-SSP can improve the detection rate of the epileptic focus compared to visual assessment and MRI. Consistency with PEZ was similar between SPM and 3D-SSP; according to their own characteristics, 3D-SSP is recommended for primary evaluation due to greater efficiency and operability of the software, while SPM is recommended for high-accuracy localization of complex lesions. Therefore, joint application of both software packages may be the best solution for FDG-PET analysis of epileptic focus localization.

SUBMITTER: Wang K 

PROVIDER: S-EPMC5037321 | biostudies-literature | 2016

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparative Study of Voxel-Based Epileptic Foci Localization Accuracy between Statistical Parametric Mapping and Three-dimensional Stereotactic Surface Projection.

Wang Kailiang K   Liu Tinghong T   Zhao Xiaobin X   Xia XiaoTong X   Zhang Kai K   Qiao Hui H   Zhang Jianguo J   Meng Fangang F  

Frontiers in neurology 20160927


<h4>Introduction</h4>Fluorine-18-fluorodeoxyglucose positron-emission tomography (<sup>18</sup>F-FDG-PET) is widely used to help localize the hypometabolic epileptogenic focus for presurgical evaluation of drug-refractory epilepsy patients. Two voxel-based brain mapping methods to interpret <sup>18</sup>F-FDG-PET, statistical parametric mapping (SPM) and three-dimensional stereotactic surface projection (3D-SSP), improve the detection rate of seizure foci. This study aimed to compare the consist  ...[more]

Similar Datasets

| S-EPMC6759804 | biostudies-literature
| S-EPMC6124809 | biostudies-literature
| S-EPMC8211129 | biostudies-literature
| S-EPMC4686971 | biostudies-literature
| S-EPMC8087271 | biostudies-literature
| S-EPMC3799958 | biostudies-literature
| S-EPMC3746204 | biostudies-other
| S-EPMC9035653 | biostudies-literature
| S-EPMC4710355 | biostudies-literature
| S-EPMC4782984 | biostudies-literature