In vivo MEMRI characterization of brain metastases using a 3D Look-Locker T1-mapping sequence.


ABSTRACT: Although MEMRI (Manganese Enhanced MRI) informations were obtained on primary tumors in small animals, MEMRI data on metastases are lacking. Thus, our goal was to determine if 3D Look-Locker T1 mapping was an efficient method to evaluate Mn ions transport in brain metastases in vivo. The high spatial resolution in 3D (156?×?156?×?218??m) of the sequence enabled to detect metastases of 0.3?mm3. In parallel, the T1 quantitation enabled to distinguish three populations of MDA-MB-231 derived brain metastases after MnCl2 intravenous injection: one with a healthy blood-tumor barrier that did not internalize Mn2+ ions, and two others, which T1 shortened drastically by 54.2% or 24%. Subsequent scans of the mice, enabled by the fast acquisition (23?min), demonstrated that these T1 reached back their pre-injection values in 24?h. Contrarily to metastases, the T1 of U87-MG glioma remained 26.2% shorter for one week. In vitro results supported the involvement of the Transient Receptor Potential channels and the Calcium-Sensing Receptor in the uptake and efflux of Mn2+ ions, respectively. This study highlights the ability of the 3D Look-Locker T1 mapping sequence to study heterogeneities (i) amongst brain metastases and (ii) between metastases and glioma regarding Mn transport.

SUBMITTER: Castets CR 

PROVIDER: S-EPMC5171659 | biostudies-literature | 2016 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

In vivo MEMRI characterization of brain metastases using a 3D Look-Locker T1-mapping sequence.

Castets Charles R CR   Koonjoo Néha N   Hertanu Andreea A   Voisin Pierre P   Franconi Jean-Michel JM   Miraux Sylvain S   Ribot Emeline J EJ  

Scientific reports 20161220


Although MEMRI (Manganese Enhanced MRI) informations were obtained on primary tumors in small animals, MEMRI data on metastases are lacking. Thus, our goal was to determine if 3D Look-Locker T1 mapping was an efficient method to evaluate Mn ions transport in brain metastases in vivo. The high spatial resolution in 3D (156 × 156 × 218 μm) of the sequence enabled to detect metastases of 0.3 mm<sup>3</sup>. In parallel, the T1 quantitation enabled to distinguish three populations of MDA-MB-231 deri  ...[more]

Similar Datasets

| S-EPMC5679534 | biostudies-literature
| S-EPMC4393277 | biostudies-literature
| S-EPMC6960582 | biostudies-literature
| S-EPMC5457913 | biostudies-literature
| S-EPMC5811329 | biostudies-literature
| S-EPMC3785574 | biostudies-other
| S-EPMC6970284 | biostudies-literature
| S-EPMC5518207 | biostudies-other
| S-EPMC8197608 | biostudies-literature
| S-EPMC6291442 | biostudies-literature