Unknown

Dataset Information

0

Improvement of Fast Model-Based Acceleration of Parameter Look-Locker T1 Mapping.


ABSTRACT: Quantitative mapping is desirable in many scientific and clinical magneric resonance imaging (MRI) applications. Recent inverse recovery-look locker sequence enables single-shot T1 mapping with a time of a few seconds but the main computational load is directed into offline reconstruction, which can take from several minutes up to few hours. In this study we proposed improvement of model-based approach for T1-mapping by introduction of two steps fitting procedure. We provided analysis of further reduction of k-space data, which lead us to decrease of computational time and perform simulation of multi-slice development. The region of interest (ROI) analysis of human brain measurements with two different initial models shows that the differences between mean values with respect to a reference approach are in white matter-0.3% and 1.1%, grey matter-0.4% and 1.78% and cerebrospinal fluid-2.8% and 11.1% respectively. With further improvements we were able to decrease the time of computational of single slice to 6.5 min and 23.5 min for different initial models, which has been already not achieved by any other algorithm. In result we obtained an accelerated novel method of model-based image reconstruction in which single iteration can be performed within few seconds on home computer.

SUBMITTER: Staniszewski M 

PROVIDER: S-EPMC6960582 | biostudies-literature | 2019 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Improvement of Fast Model-Based Acceleration of Parameter Look-Locker T<sub>1</sub> Mapping.

Staniszewski Michał M   Klose Uwe U  

Sensors (Basel, Switzerland) 20191205 24


Quantitative mapping is desirable in many scientific and clinical magneric resonance imaging (MRI) applications. Recent inverse recovery-look locker sequence enables single-shot T<sub>1</sub> mapping with a time of a few seconds but the main computational load is directed into offline reconstruction, which can take from several minutes up to few hours. In this study we proposed improvement of model-based approach for T<sub>1</sub>-mapping by introduction of two steps fitting procedure. We provid  ...[more]

Similar Datasets

| S-EPMC4393277 | biostudies-literature
| S-EPMC5679534 | biostudies-literature
| S-EPMC5171659 | biostudies-literature
| S-EPMC5457913 | biostudies-literature
| S-EPMC5811329 | biostudies-literature
| S-EPMC3785574 | biostudies-other
| S-EPMC6970284 | biostudies-literature
| S-EPMC6289851 | biostudies-literature
| S-EPMC8245629 | biostudies-literature
| S-EPMC4636240 | biostudies-literature