Unknown

Dataset Information

0

Identification and Characterization of Human Proteoforms by Top-Down LC-21 Tesla FT-ICR Mass Spectrometry.


ABSTRACT: Successful high-throughput characterization of intact proteins from complex biological samples by mass spectrometry requires instrumentation capable of high mass resolving power, mass accuracy, sensitivity, and spectral acquisition rate. These limitations often necessitate the performance of hundreds of LC-MS/MS experiments to obtain reasonable coverage of the targeted proteome, which is still typically limited to molecular weights below 30 kDa. The National High Magnetic Field Laboratory (NHMFL) recently installed a 21 T FT-ICR mass spectrometer, which is part of the NHMFL FT-ICR User Facility and available to all qualified users. Here we demonstrate top-down LC-21 T FT-ICR MS/MS of intact proteins derived from human colorectal cancer cell lysate. We identified a combined total of 684 unique protein entries observed as 3238 unique proteoforms at a 1% false discovery rate, based on rapid, data-dependent acquisition of collision-induced and electron-transfer dissociation tandem mass spectra from just 40 LC-MS/MS experiments. Our identifications included 372 proteoforms with molecular weights over 30 kDa detected at isotopic resolution, which substantially extends the accessible mass range for high-throughput top-down LC-MS/MS.

SUBMITTER: Anderson LC 

PROVIDER: S-EPMC5353847 | biostudies-literature | 2017 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Identification and Characterization of Human Proteoforms by Top-Down LC-21 Tesla FT-ICR Mass Spectrometry.

Anderson Lissa C LC   DeHart Caroline J CJ   Kaiser Nathan K NK   Fellers Ryan T RT   Smith Donald F DF   Greer Joseph B JB   LeDuc Richard D RD   Blakney Greg T GT   Thomas Paul M PM   Kelleher Neil L NL   Hendrickson Christopher L CL  

Journal of proteome research 20161212 2


Successful high-throughput characterization of intact proteins from complex biological samples by mass spectrometry requires instrumentation capable of high mass resolving power, mass accuracy, sensitivity, and spectral acquisition rate. These limitations often necessitate the performance of hundreds of LC-MS/MS experiments to obtain reasonable coverage of the targeted proteome, which is still typically limited to molecular weights below 30 kDa. The National High Magnetic Field Laboratory (NHMFL  ...[more]

Similar Datasets

| S-EPMC4095805 | biostudies-literature
| S-EPMC4427557 | biostudies-literature
2016-07-22 | MSV000079978 | MassIVE
| S-EPMC7775878 | biostudies-literature
| S-EPMC8543976 | biostudies-literature
| S-EPMC6109964 | biostudies-literature
| S-EPMC8226665 | biostudies-literature
| S-EPMC5711562 | biostudies-literature
2020-08-19 | MSV000085978 | MassIVE
| S-EPMC7031845 | biostudies-literature