Unknown

Dataset Information

0

A Simple Composite Metric for the Assessment of Glycemic Status from Continuous Glucose Monitoring Data: Implications for Clinical Practice and the Artificial Pancreas.


ABSTRACT: BACKGROUND:The potential clinical benefits of continuous glucose monitoring (CGM) have been recognized for many years, but CGM is used by a small fraction of patients with diabetes. One obstacle to greater use of the technology is the lack of simplified tools for assessing glycemic control from CGM data without complicated visual displays of data. METHODS:We developed a simple new metric, the personal glycemic state (PGS), to assess glycemic control solely from continuous glucose monitoring data. PGS is a composite index that assesses four domains of glycemic control: mean glucose, glycemic variability, time in range and frequency and severity of hypoglycemia. The metric was applied to data from six clinical studies for the G4 Platinum continuous glucose monitoring system (Dexcom, San Diego, CA). The PGS was also applied to data from a study of artificial pancreas comparing results from open loop and closed loop in adolescents and in adults. RESULTS:The new metric for glycemic control, PGS, was able to characterize the quality of glycemic control in a wide range of study subjects with various mean glucose, minimal, moderate, and excessive glycemic variability and subjects on open loop versus closed loop control. CONCLUSION:A new composite metric for the assessment of glycemic control based on CGM data has been defined for use in assessing glycemic control in clinical practice and research settings. The new metric may help rapidly identify problems in glycemic control and may assist with optimizing diabetes therapy during time-constrained physician office visits.

SUBMITTER: Hirsch IB 

PROVIDER: S-EPMC5467104 | biostudies-literature | 2017 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

A Simple Composite Metric for the Assessment of Glycemic Status from Continuous Glucose Monitoring Data: Implications for Clinical Practice and the Artificial Pancreas.

Hirsch Irl B IB   Balo Andrew K AK   Sayer Kevin K   Garcia Arturo A   Buckingham Bruce A BA   Peyser Thomas A TA  

Diabetes technology & therapeutics 20170601 S3


<h4>Background</h4>The potential clinical benefits of continuous glucose monitoring (CGM) have been recognized for many years, but CGM is used by a small fraction of patients with diabetes. One obstacle to greater use of the technology is the lack of simplified tools for assessing glycemic control from CGM data without complicated visual displays of data.<h4>Methods</h4>We developed a simple new metric, the personal glycemic state (PGS), to assess glycemic control solely from continuous glucose  ...[more]

Similar Datasets

| S-EPMC4717501 | biostudies-literature
| S-EPMC5951059 | biostudies-literature
| S-EPMC4596806 | biostudies-literature
| S-EPMC7884232 | biostudies-literature
| S-EPMC7467959 | biostudies-literature
| S-EPMC5467105 | biostudies-literature
| S-EPMC7576953 | biostudies-literature
| S-EPMC3705721 | biostudies-literature
| S-EPMC6468940 | biostudies-literature
| S-EPMC10699474 | biostudies-literature