Pratt Rosalind R Hutchinson J Ciaran JC Melbourne Andrew A Zuluaga Maria A MA Virasami Alex A Vercauteren Tom T Ourselin Sebastien S Sebire Neil J NJ Arthurs Owen J OJ David Anna L AL
Placenta 20171003
Micro-CT provides 3D volume imaging with spatial resolution at the micrometre scale. We investigated the optimal human placenta tissue preparation (contrast agent, perfusion pressure, perfusion location and perfusion vessel) and imaging (energy, target material, exposure time and frames) parameters. Microfil (Flow Tech, Carver, MA) produced better fill than Barium sulphate (84.1%(±11.5%)vs70.4%(±18.02%) p = 0.01). Perfusion via umbilical artery produced better fill than via chorionic vessels (83 ...[more]