Unknown

Dataset Information

0

Dixon-VIBE Deep Learning (DIVIDE) Pseudo-CT Synthesis for Pelvis PET/MR Attenuation Correction.


ABSTRACT: Whole-body attenuation correction (AC) is still challenging in combined PET/MR scanners. We describe Dixon-VIBE Deep Learning (DIVIDE), a deep-learning network that allows synthesizing pelvis pseudo-CT maps based only on the standard Dixon volumetric interpolated breath-hold examination (Dixon-VIBE) images currently acquired for AC in some commercial scanners. Methods: We propose a network that maps between the four 2-dimensional (2D) Dixon MR images (water, fat, in-phase, and out-of-phase) and their corresponding 2D CT image. In contrast to previous methods, we used transposed convolutions to learn the up-sampling parameters, we used whole 2D slices to provide context information, and we pretrained the network with brain images. Twenty-eight datasets obtained from 19 patients who underwent PET/CT and PET/MR examinations were used to evaluate the proposed method. We assessed the accuracy of the ?-maps and reconstructed PET images by performing voxel- and region-based analysis comparing the SUVs (in g/mL) obtained after AC using the Dixon-VIBE (PETDixon), DIVIDE (PETDIVIDE), and CT-based (PETCT) methods. Additionally, the bias in quantification was estimated in synthetic lesions defined in the prostate, rectum, pelvis, and spine. Results: Absolute mean relative change values relative to CT AC were lower than 2% on average for the DIVIDE method in every region of interest except for bone tissue, where it was lower than 4% and 6.75 times smaller than the relative change of the Dixon method. There was an excellent voxel-by-voxel correlation between PETCT and PETDIVIDE (R 2 = 0.9998, P < 0.01). The Bland-Altman plot between PETCT and PETDIVIDE showed that the average of the differences and the variability were lower (mean PETCT-PETDIVIDE SUV, 0.0003; PETCT-PETDIVIDE SD, 0.0094; 95% confidence interval, [-0.0180,0.0188]) than the average of differences between PETCT and PETDixon (mean PETCT-PETDixon SUV, 0.0006; PETCT-PETDixon SD, 0.0264; 95% confidence interval, [-0.0510,0.0524]). Statistically significant changes in PET data quantification were observed between the 2 methods in the synthetic lesions, with the largest improvement in femur and spine lesions. Conclusion: The DIVIDE method can accurately synthesize a pelvis pseudo-CT scan from standard Dixon-VIBE images, allowing for accurate AC in combined PET/MR scanners. Additionally, our implementation allows rapid pseudo-CT synthesis, making it suitable for routine applications and even allowing retrospective processing of Dixon-VIBE data.

SUBMITTER: Torrado-Carvajal A 

PROVIDER: S-EPMC6910626 | biostudies-literature | 2019 Mar

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC5932530 | biostudies-literature
| S-EPMC7375929 | biostudies-literature
| S-EPMC6173790 | biostudies-literature
| S-EPMC4090355 | biostudies-other
| S-EPMC5877454 | biostudies-literature
| S-EPMC6779234 | biostudies-literature
| S-EPMC3869851 | biostudies-other
| S-EPMC3353415 | biostudies-literature
| S-EPMC4891225 | biostudies-literature
| S-EPMC3477199 | biostudies-other