Unknown

Dataset Information

0

Data on performance of air stripping tower- PAC integrated system for removing of odor, taste, dye and organic materials from drinking water-A case study in Saqqez, Iran.


ABSTRACT: Unpleasant taste or smell are more importantly constituents of drinking-water, lead to complaints from consumers. Dye and organic matter as well change in disinfection practice may generate taste and an odorous compound in treated water. According to low efficiency of conventional methods to remove taste and odor compounds, present study was aimed to evaluate the performance of air stripping tower- Poly Aluminum Chloride (PAC) integrated system to remove odor and taste, dye and organic materials from drinking water. Different air to water ratio and PAC doses were used to remove considered parameters in certain condition. The results of this study indicated that the maximum removal efficiency of 86.2, 76.47, 58.46 and 41.27% of taste and odor, dye, COD and TOC were achieved by the air stripping tower- PAC integrated system, respectively. However, the physico-chemical characteristics of water and adsorbent effect on the of substances removal efficiency considerably. It can be stated that the air striping tower - PAC integrated system is able to reduce the odor and taste-causing substances and organic matter to a level which is recommended by the Institute of Standards and Industrial Research of Iran.

SUBMITTER: Pirsaheb M 

PROVIDER: S-EPMC5997578 | biostudies-literature | 2018 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Data on performance of air stripping tower- PAC integrated system for removing of odor, taste, dye and organic materials from drinking water-A case study in Saqqez, Iran.

Pirsaheb Meghdad M   Mohammadi Jalil J   Khosravi Touba T   Sharafi Hooshmnd H   Moradi Masoud M  

Data in brief 20180412


Unpleasant taste or smell are more importantly constituents of drinking-water, lead to complaints from consumers. Dye and organic matter as well change in disinfection practice may generate taste and an odorous compound in treated water. According to low efficiency of conventional methods to remove taste and odor compounds, present study was aimed to evaluate the performance of air stripping tower- Poly Aluminum Chloride (PAC) integrated system to remove odor and taste, dye and organic materials  ...[more]

Similar Datasets

| S-EPMC8050797 | biostudies-literature
| S-EPMC4988214 | biostudies-literature
| S-EPMC6604050 | biostudies-literature
| S-EPMC6082279 | biostudies-literature
| S-EPMC6033408 | biostudies-literature
| S-EPMC3175104 | biostudies-literature
| S-EPMC6356868 | biostudies-literature
| S-EPMC5856759 | biostudies-literature
| S-EPMC6127982 | biostudies-literature
| PRJEB39665 | ENA