Unknown

Dataset Information

0

Compliance With the National SEP-1 Quality Measure and Association With Sepsis Outcomes: A Multicenter Retrospective Cohort Study.


ABSTRACT: OBJECTIVES:Many septic patients receive care that fails the Centers for Medicare and Medicaid Services' SEP-1 measure, but it is unclear whether this reflects meaningful lapses in care, differences in clinical characteristics, or excessive rigidity of the "all-or-nothing" measure. We compared outcomes in cases that passed versus failed SEP-1 during the first 2 years after the measure was implemented. DESIGN:Retrospective cohort study. SETTING:Seven U.S. hospitals. PATIENTS:Adult patients included in SEP-1 reporting between October 2015 and September 2017. INTERVENTIONS:None. MEASUREMENTS AND MAIN RESULTS:Of 851 sepsis cases in the cohort, 281 (33%) passed SEP-1 and 570 (67%) failed. SEP-1 failures had higher rates of septic shock (20% vs 9%; p < 0.001), hospital-onset sepsis (11% vs 4%; p = 0.001), and vague presenting symptoms (46% vs 30%; p < 0.001). The most common reasons for failure were omission of 3- and 6-hour lactate measurements (228/570 failures, 40%). Only 86 of 570 failures (15.1%) had greater than 3-hour delays until broad-spectrum antibiotics. Cases that failed SEP-1 had higher in-hospital mortality rates (18.4% vs 11.0%; odds ratio, 1.82; 95% CI, 1.19-2.80; p = 0.006), but this association was no longer significant after adjusting for differences in clinical characteristics and severity of illness (adjusted odds ratio, 1.36; 95% CI, 0.85-2.18; p = 0.205). Delays of greater than 3 hours until antibiotics were significantly associated with death (adjusted odds ratio, 1.94; 95% CI, 1.04-3.62; p = 0.038), whereas failing SEP-1 for any other reason was not (adjusted odds ratio, 1.10; 95% CI, 0.70-1.72; p = 0.674). CONCLUSIONS:Crude mortality rates were higher in sepsis cases that failed versus passed SEP-1, but there was no difference after adjusting for clinical characteristics and severity of illness. Delays in antibiotic administration were associated with higher mortality but only accounted for a small fraction of SEP-1 failures. SEP-1 may not clearly differentiate between high- and low-quality care, and detailed risk adjustment is necessary to properly interpret associations between SEP-1 compliance and mortality.

SUBMITTER: Rhee C 

PROVIDER: S-EPMC6138564 | biostudies-literature | 2018 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Objectives</h4>Many septic patients receive care that fails the Centers for Medicare and Medicaid Services' SEP-1 measure, but it is unclear whether this reflects meaningful lapses in care, differences in clinical characteristics, or excessive rigidity of the "all-or-nothing" measure. We compared outcomes in cases that passed versus failed SEP-1 during the first 2 years after the measure was implemented.<h4>Design</h4>Retrospective cohort study.<h4>Setting</h4>Seven U.S. hospitals.<h4>Patien  ...[more]

Similar Datasets

| S-EPMC7174506 | biostudies-literature
| S-EPMC6901718 | biostudies-literature
| S-EPMC11003155 | biostudies-literature
| S-EPMC6595205 | biostudies-literature
| S-EPMC5525152 | biostudies-literature
| S-EPMC6625440 | biostudies-literature
| S-EPMC11000341 | biostudies-literature
| S-EPMC7822757 | biostudies-literature
| S-EPMC6689078 | biostudies-literature
| S-EPMC5516667 | biostudies-other