High-speed raster-scanning synchrotron serial microcrystallography with a high-precision piezo-scanner.


ABSTRACT: The Frontier Microfocus Macromolecular Crystallography (FMX) beamline at the National Synchrotron Light Source II with its 1?µm beam size and photon flux of 3 × 1012 photons?s-1 at a photon energy of 12.66?keV has reached unprecedented dose rates for a structural biology beamline. The high dose rate presents a great advantage for serial microcrystallography in cutting measurement time from hours to minutes. To provide the instrumentation basis for such measurements at the full flux of the FMX beamline, a high-speed, high-precision goniometer based on a unique XYZ piezo positioner has been designed and constructed. The piezo-based goniometer is able to achieve sub-100?nm raster-scanning precision at over 10 grid-linepairs?s-1 frequency for fly scans of a 200?µm-wide raster. The performance of the scanner in both laboratory and serial crystallography measurements up to the maximum frame rate of 750?Hz of the Eiger 16M's 4M region-of-interest mode has been verified in this work. This unprecedented experimental speed significantly reduces serial-crystallography data collection time at synchrotrons, allowing utilization of the full brightness of the emerging synchrotron radiation facilities.

SUBMITTER: Gao Y 

PROVIDER: S-EPMC6140394 | biostudies-literature | 2018 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

High-speed raster-scanning synchrotron serial microcrystallography with a high-precision piezo-scanner.

Gao Yuan Y   Xu Weihe W   Shi Wuxian W   Soares Alexei A   Jakoncic Jean J   Myers Stuart S   Martins Bruno B   Skinner John J   Liu Qun Q   Bernstein Herbert H   McSweeney Sean S   Nazaretski Evgeny E   Fuchs Martin R MR  

Journal of synchrotron radiation 20180823 Pt 5


The Frontier Microfocus Macromolecular Crystallography (FMX) beamline at the National Synchrotron Light Source II with its 1 µm beam size and photon flux of 3 × 10<sup>12</sup> photons s<sup>-1</sup> at a photon energy of 12.66 keV has reached unprecedented dose rates for a structural biology beamline. The high dose rate presents a great advantage for serial microcrystallography in cutting measurement time from hours to minutes. To provide the instrumentation basis for such measurements at the f  ...[more]

Similar Datasets

| S-EPMC4427202 | biostudies-literature
| S-EPMC4629865 | biostudies-other
| S-EPMC4498415 | biostudies-literature
| S-EPMC5588887 | biostudies-literature
| S-EPMC4129423 | biostudies-literature
| S-EPMC6892803 | biostudies-literature
| S-EPMC7948854 | biostudies-literature
| S-EPMC7065608 | biostudies-literature
| S-EPMC5668862 | biostudies-literature
| S-EPMC5501561 | biostudies-literature