Unknown

Dataset Information

0

Antenatal placental assessment in the prediction of adverse pregnancy outcome after reduced fetal movement.


ABSTRACT: OBJECTIVE:To assess the value of in utero placental assessment in predicting adverse pregnancy outcome after reported reduced fetal movements (RFM). METHOD:A non-interventional prospective cohort study of women (N = 300) with subjective RFM at ?28 weeks' gestation in singleton non-anomalous pregnancies at a UK tertiary maternity hospital. Clinical, sonographic (fetal weight, placental size and maternal, fetal and placental arterial Doppler) and biochemical (maternal serum hCG, hPL, progesterone, PlGF and sFlt-1) assessment was conducted. Multiple logistic regression identified combinations of measurements (models) most predictive of adverse pregnancy outcome (perinatal mortality, birth weight <10th centile, five minute Apgar score <7, umbilical arterial pH <7.1 or base excess <-10, neonatal intensive care admission). Models were compared by test performance characteristics (ROC curve, sensitivity, specificity, positive/negative predictive value, positive/negative likelihood ratios) against baseline care (estimated fetal weight centile, amniotic fluid index and gestation at presentation). RESULTS:61 (20.6%) pregnancies ended in adverse outcome. Models incorporating PlGF/sFlt-1 ratio and umbilical artery free loop Doppler impedance demonstrated modest improvement in ROC area for adverse outcome (baseline care 0.69 vs. proposed models 0.73-0.76, p<0.05). However, there was little improvement in other test characteristics (baseline vs. best proposed model: sensitivity 21.7% [95% confidence interval 13.1-33.6] vs. 35.8%% [24.4-49.3], specificity 96.6% [93.4-98.3] vs. 94.7% [90.7-97.0], PPV 61.9% [40.9-79.3] vs. 63.3% [45.5-78.1], NPV 82.8% [77.9-86.8] vs. 85.2% [80.0-89.2], positive LR 6.3 [2.8-14.6] vs. 6.7 [3.4-3.3], negative LR 0.81 [0.71-0.93] vs. 0.68 [0.55-0.83]) and wide confidence intervals. Negative post-test probability remained high (16.7% vs. 14.0%). CONCLUSION:Antenatal placental assessment may improve identification of RFM pregnancies at highest risk of adverse pregnancy outcome but further work is required to understand and refine currently available outcome definitions and diagnostic techniques to improve clinical utility.

SUBMITTER: Higgins LE 

PROVIDER: S-EPMC6218043 | biostudies-literature | 2018

REPOSITORIES: biostudies-literature

altmetric image

Publications

Antenatal placental assessment in the prediction of adverse pregnancy outcome after reduced fetal movement.

Higgins Lucy E LE   Myers Jenny E JE   Sibley Colin P CP   Johnstone Edward D ED   Heazell Alexander E P AEP  

PloS one 20181105 11


<h4>Objective</h4>To assess the value of in utero placental assessment in predicting adverse pregnancy outcome after reported reduced fetal movements (RFM).<h4>Method</h4>A non-interventional prospective cohort study of women (N = 300) with subjective RFM at ≥28 weeks' gestation in singleton non-anomalous pregnancies at a UK tertiary maternity hospital. Clinical, sonographic (fetal weight, placental size and maternal, fetal and placental arterial Doppler) and biochemical (maternal serum hCG, hPL  ...[more]

Similar Datasets

| S-EPMC4488264 | biostudies-literature
| S-EPMC6973256 | biostudies-literature
| S-EPMC6675049 | biostudies-literature
| S-EPMC4881909 | biostudies-literature
| EGAC00001000582 | EGA
| S-EPMC8748269 | biostudies-literature
| S-EPMC9270931 | biostudies-literature
| S-EPMC4701427 | biostudies-literature
| S-EPMC8382909 | biostudies-literature
| S-EPMC9313890 | biostudies-literature