Unknown

Dataset Information

0

Synthesis and Preclinical Characterization of the PSMA-Targeted Hybrid Tracer PSMA-I&F for Nuclear and Fluorescence Imaging of Prostate Cancer.


ABSTRACT: The prostate-specific membrane antigen (PSMA)-targeted radiotracers 68Ga/177Lu-PSMA-I&T and 99mTc-PSMA-I&S (for i maging and s urgery) are currently successfully used for clinical PET imaging, radionuclide therapy, and radioguided surgery of metastatic prostate cancer. To additionally exploit the high sensitivity and spatial resolution of fluorescence imaging for improved surgical guidance, a PSMA-I&T-based hybrid tracer, PSMA-I&F (DOTAGA-k(Sulfo-Cy5)-y-nal-k-Sub-KuE), has been developed and evaluated. Methods: The in vitro PSMA-targeting efficiency of PSMA-I&F, the reference PSMA-I&T, and their corresponding natGa-/68Ga- and natLu/177Lu counterparts was determined in LNCaP cells via competitive binding assays (IC50) and dual-tracer radioligand and fluorescence internalization studies. Biodistribution and small-animal PET imaging studies were performed in CB17 SCID and LNCaP xenograft-bearing SHO mice, respectively, and complemented by intraoperative far-red fluorescence imaging using a clinical laparoscope. Additionally, fully automated serial cryosectioning and fluorescence imaging of 1 tumor-bearing animal as well as PSMA immunohistochemistry and fluorescence microscopy of organ cryosections (tumor, kidney, spleen) were also performed. Results: Compared with the parent PSMA-I&T analogs, the PSMA affinities of PSMA-I&F and its natGa-/natLu-complexes remained high and unaffected by dye conjugation (7.9 < IC50 < 10.5 nM for all ligands). The same was observed for the internalization of 68Ga- and 177Lu-PSMA-I&F. In vivo, blood clearance of 68Ga- and 177Lu-PSMA-I&F was only slightly delayed by high plasma protein binding (94%-95%), and very low accumulation in nontarget organs was observed already at 1 h after injection. Dynamic PET imaging confirmed PSMA-specific (as demonstrated by coinjection of 2-PMPA) uptake into the LNCaP xenograft (4.5% ± 1.8 percentage injected dose per gram) and the kidneys (106% ± 23 percentage injected dose per gram). Tumor-to-background ratios of 2.1, 5.2, 9.6, and 9.6 for blood, liver, intestines, and muscle, respectively, at 1 h after injection led to excellent imaging contrast in 68Ga-PSMA-I&F PET and in intraoperative fluorescence imaging. Furthermore, fluorescence imaging of tissue cryosections allowed high-resolution visualization of intraorgan PSMA-I&F distribution in vivo and its correlation with PSMA expression as determined by immunohistochemistry. Conclusion: Thus, with its high PSMA-targeting efficiency and favorable pharmacokinetic profile, 68Ga/177Lu-PSMA-I&F serves as an excellent proof-of-concept compound for the general feasibility of PSMA-I&T-based hybrid imaging. The PSMA-I&T scaffold represents a versatile PSMA-targeted lead structure, allowing relatively straightforward adaptation to the different structural requirements of dedicated nuclear or hybrid imaging agents.

SUBMITTER: Schottelius M 

PROVIDER: S-EPMC6354225 | biostudies-literature | 2019 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Synthesis and Preclinical Characterization of the PSMA-Targeted Hybrid Tracer PSMA-I&F for Nuclear and Fluorescence Imaging of Prostate Cancer.

Schottelius Margret M   Wurzer Alexander A   Wissmiller Katharina K   Beck Roswitha R   Koch Maximilian M   Gorpas Dimitrios D   Notni Johannes J   Buckle Tessa T   van Oosterom Matthias N MN   Steiger Katja K   Ntziachristos Vasilis V   Schwaiger Markus M   van Leeuwen Fijs W B FWB   Wester Hans-Jürgen HJ  

Journal of nuclear medicine : official publication, Society of Nuclear Medicine 20180920 1


The prostate-specific membrane antigen (PSMA)-targeted radiotracers <sup>68</sup>Ga/<sup>177</sup>Lu-PSMA-I&T and <sup>99m</sup>Tc-PSMA-I&S (for <b><u>i</u></b> maging and <b><u>s</u></b> urgery) are currently successfully used for clinical PET imaging, radionuclide therapy, and radioguided surgery of metastatic prostate cancer. To additionally exploit the high sensitivity and spatial resolution of fluorescence imaging for improved surgical guidance, a PSMA-I&T-based hybrid tracer, PSMA-I&F (DOT  ...[more]

Similar Datasets

| S-EPMC4452638 | biostudies-literature
| S-EPMC5537616 | biostudies-literature
| S-EPMC5728657 | biostudies-literature
| S-EPMC5650330 | biostudies-literature
| S-EPMC6910127 | biostudies-literature
| S-EPMC6980512 | biostudies-literature
| S-EPMC7605099 | biostudies-literature
| S-EPMC7918517 | biostudies-literature
| S-EPMC5897267 | biostudies-literature
| S-EPMC9921851 | biostudies-literature