Fat suppression for ultrashort echo time imaging using a single-point Dixon method.


ABSTRACT: PURPOSE:In ultrashort echo time (UTE) imaging, fat suppression can improve short T2 * contrast but can also reduce short T2 * signals. The conventional two-point Dixon (2p-Dixon) method does not perform well due to short T2 * decay. In this study, we propose a new method to suppress fat for high contrast UTE imaging of short T2 tissues, utilizing a single-point Dixon (1p-Dixon) method. METHODS:The proposed method utilizes dual-echo UTE imaging, where UTE is followed by the second TE, chosen flexibly. Fat is estimated by applying a 1p-Dixon method to the non-UTE image after correction of phase errors, which is used to suppress fat in the UTE image. In vivo ankle and knee imaging were performed at 3 T to evaluate the proposed method. RESULT:It was observed that fat and water signals in tendons were misestimated by the 2p-Dixon method due to signal decay, while the 1p-Dixon method showed reliable fat and water separation not affected by the short T2 * signal decay. Compared with the conventional chemical shift based fat saturation technique, the 1p-Dixon based approach showed much stronger signal intensities in the Achilles, quadriceps, and patellar tendons, with significantly improved contrast to noise ratios (CNRs) of 11.8 ± 2.2, 16.0 ± 1.6, and 26.8 ± 1.3 with the 1p-Dixon method and 0.6 ± 0.2, 4.6 ± 1.0, and 17.5 ± 1.4 with regular fat saturation, respectively. CONCLUSION:The proposed 1p-Dixon based fat suppression allows more flexible selection of imaging parameters and more accurate fat and water separation over the conventional 2p-Dixon in UTE imaging. Moreover, the proposed method provides much improved CNR for short T2 tissues over the conventional fat saturation method.

SUBMITTER: Jang H 

PROVIDER: S-EPMC6476675 | biostudies-literature | 2019 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Fat suppression for ultrashort echo time imaging using a single-point Dixon method.

Jang Hyungseok H   Carl Michael M   Ma Yajun Y   Jerban Saeed S   Guo Tan T   Zhao Wei W   Chang Eric Y EY   Du Jiang J  

NMR in biomedicine 20190215 5


<h4>Purpose</h4>In ultrashort echo time (UTE) imaging, fat suppression can improve short T<sub>2</sub> * contrast but can also reduce short T<sub>2</sub> * signals. The conventional two-point Dixon (2p-Dixon) method does not perform well due to short T<sub>2</sub> * decay. In this study, we propose a new method to suppress fat for high contrast UTE imaging of short T<sub>2</sub> tissues, utilizing a single-point Dixon (1p-Dixon) method.<h4>Methods</h4>The proposed method utilizes dual-echo UTE i  ...[more]

Similar Datasets

| S-EPMC6717024 | biostudies-literature
| S-EPMC7375929 | biostudies-literature
| S-EPMC6414254 | biostudies-literature
| S-EPMC5123983 | biostudies-literature
| S-EPMC7479001 | biostudies-literature
| S-EPMC6443501 | biostudies-literature
| S-EPMC6435423 | biostudies-literature
| S-EPMC6097905 | biostudies-literature