Unknown

Dataset Information

0

Time-Delayed Integration-Spectral Flow Cytometer (TDI-SFC) for Low-Abundance-Cell Immunophenotyping.


ABSTRACT: We describe a unique flow cytometer (TDI-SFC) for the immunophenotyping of low-abundance cells, particularly when cell counts are sample-limited and operationally difficult for analysis by fluorescence microscopy (>100 cells) or multiparameter flow cytometry (MFC, <10?000 cells). TDI-SFC combines the high spectral resolution of spectral flow cytometry (SFC) with a CCD operated in time-delayed integration (TDI) for improved duty cycle and sensitivity. Cells were focused with a 1D-sheathing microfluidic device, and fluorescence emission generated from a 488 nm laser was collected by epi-illumination and dispersed along one axis of a CCD by a spectrograph. Along the other axis, the CCD's shift rate was clocked at a rate that closely matched the cells' velocity through the field of view. This TDI-SFC format allowed the CCD shutter to remain open during signal acquisition, providing a duty cycle ?100% and assurance that ?95% cells were interrogated. We used fluorescent beads to optimize synchronization of TDI clocking with the sheathed-cell velocity and to improve sensitivity via the excitation intensity, epi-illumination numerical aperture, and integration time. TDI achieved integrated signals of 106 counts at a signal-to-noise ratio (SNR) of 610 for beads corresponding to a load of 4 × 105 antibodies. We also evaluated multiplexing capabilities by spectral deconvolution and undertook a proof-of-concept application to immunophenotype low-abundance cells; the demonstration consisted of immunophenotyping a model cell line, in this case SUP-B15 cells representing B-cell acute lymphoblastic leukemia (B-ALL). The B-ALL cell line was stained against a leukemic marker (terminal deoxynucleotidyl transferase, TdT), and we successfully used spectral unmixing to discriminate TdT(+) cells from TdT(-) cells even at low cell counts (?100 cells). The TDI-SFC could potentially be used in any application requiring the immunophenotyping of low-abundance cells, such as in monitoring measurable residual disease in acute leukemias following affinity enrichment of circulating leukemia cells from peripheral blood.

SUBMITTER: Hu W 

PROVIDER: S-EPMC6554645 | biostudies-literature | 2019 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Time-Delayed Integration-Spectral Flow Cytometer (TDI-SFC) for Low-Abundance-Cell Immunophenotyping.

Hu Wenting W   Soper Steven A SA   Jackson J Matt JM  

Analytical chemistry 20190313 7


We describe a unique flow cytometer (TDI-SFC) for the immunophenotyping of low-abundance cells, particularly when cell counts are sample-limited and operationally difficult for analysis by fluorescence microscopy (>100 cells) or multiparameter flow cytometry (MFC, <10 000 cells). TDI-SFC combines the high spectral resolution of spectral flow cytometry (SFC) with a CCD operated in time-delayed integration (TDI) for improved duty cycle and sensitivity. Cells were focused with a 1D-sheathing microf  ...[more]

Similar Datasets

| S-EPMC3437409 | biostudies-literature
| S-EPMC2945735 | biostudies-other
| S-EPMC4748244 | biostudies-other
| S-EPMC10790684 | biostudies-literature
| S-EPMC7855665 | biostudies-literature
| S-EPMC6423196 | biostudies-literature
| S-EPMC5514097 | biostudies-literature
| S-EPMC3084896 | biostudies-literature
| S-EPMC4928650 | biostudies-literature
| S-EPMC3341488 | biostudies-literature