Using probe electrospray ionization mass spectrometry and machine learning for detecting pancreatic cancer with high performance.


ABSTRACT: A rapid blood-based diagnostic modality to detect pancreatic ductal adenocarcinoma (PDAC) with high accuracy is an unmet medical need. The study aimed to validate a unique diagnosis system using Probe Electrospray Ionization Mass Spectrometry (PESI-MS) and Machine Learning to the diagnosis of PDAC. Peripheral blood samples were collected from a total of 322 consecutive PDAC patients and 265 controls with a family history of PDAC. Five µl of serum samples were analyzed using PESI-MS system. The mass spectra from each specimen were then fed into machine learning algorithms to discriminate between control and cancer cases. A total of 587 serum samples were analyzed. The sensitivity of the machine learning algorithm using PESI-MS profiles to identify PDAC is 90.8% with specificity of 91.7% (95% CI 83.9%-97.4% and 82.8%-97.7% respectively). Combined PESI-MS profiles with age and CA19-9 as predictors, the accuracy for stage 1 or 2 of PDAC is 92.9% and for stage 3 or 4 is 93% (95% CI 86.3-98.2; 87.9-97.4 respectively). The accuracy and simplicity of the PESI-MS profiles combined with machine learning provide an opportunity to detect PDAC at an early stage and must be applicable to the examination of at-risk populations.

SUBMITTER: Chung WY 

PROVIDER: S-EPMC7013221 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Using probe electrospray ionization mass spectrometry and machine learning for detecting pancreatic cancer with high performance.

Chung Wen Y WY   Correa Elon E   Yoshimura Kentaro K   Chang Ming-Chu MC   Dennison Ashley A   Takeda Sen S   Chang Yu-Ting YT  

American journal of translational research 20200115 1


A rapid blood-based diagnostic modality to detect pancreatic ductal adenocarcinoma (PDAC) with high accuracy is an unmet medical need. The study aimed to validate a unique diagnosis system using Probe Electrospray Ionization Mass Spectrometry (PESI-MS) and Machine Learning to the diagnosis of PDAC. Peripheral blood samples were collected from a total of 322 consecutive PDAC patients and 265 controls with a family history of PDAC. Five µl of serum samples were analyzed using PESI-MS system. The m  ...[more]

Similar Datasets

| S-EPMC6310154 | biostudies-literature
| S-EPMC7216899 | biostudies-literature
| S-EPMC3176668 | biostudies-literature
| S-EPMC6422691 | biostudies-literature
| S-EPMC5990474 | biostudies-literature
| S-EPMC3259225 | biostudies-literature
| S-EPMC4878830 | biostudies-other
| S-EPMC5887808 | biostudies-other
| S-EPMC3769336 | biostudies-literature
| S-EPMC3075559 | biostudies-literature