Clinical evaluation of a multi-parameter customized respiratory TaqMan(®) array card compared to conventional methods in immunocompromised patients.


ABSTRACT:

Background

Respiratory viral infections can cause significant morbidity and mortality in immunocompromised patients. Conventional tests routinely available at most institutions are limited by the number of detectable pathogens, by a poor sensitivity and/or a long turnaround time.

Objectives

To compare the performance of routine conventional testing with direct fluorescent antibody assays and viral culture to a customized TaqMan® array card (TAC) real-time PCR method, targeting 24 viruses, 8 bacteria and 2 fungi simultaneously.

Study design

We collected 143 respiratory samples from 120 symptomatic immunocompromised patients. Samples for which conventional and TAC results were discordant underwent further verification testing.

Results

The TAC assay identified viral pathogens in more samples than did conventional testing (77/143 versus 27/143; McNemar P<0.0001), even when TAC results for viruses that could not be detected by conventional testing were excluded from analysis (59/143 versus 26/143; P<0.0001). In addition, the TAC assay identified 18 samples with non-viral pathogens. Verification testing confirmed positive TAC results for 50 out of 55 samples for which conventional testing was negative. Two out of three samples with a positive conventional test but negative TAC result were confirmed positive. A viral and a total pathogen co-infection rate of 5.6% and 11.8% were found, respectively.

Conclusions

The customized TAC assay resulted in a significantly increased identification of respiratory viruses. This study provides a practical real-life assessment of the performance of the TAC assay in a population for whom rapid and accurate diagnosis of viral and atypical pathogens is crucial for appropriate clinical management.

SUBMITTER: Steensels D 

PROVIDER: S-EPMC7106552 | biostudies-literature | 2015 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Clinical evaluation of a multi-parameter customized respiratory TaqMan(®) array card compared to conventional methods in immunocompromised patients.

Steensels Deborah D   Reynders Marijke M   Descheemaeker Patrick P   Curran Martin D MD   Jacobs Frédérique F   Denis Olivier O   Delforge Marie-Luce ML   Montesinos Isabel I  

Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology 20150903


<h4>Background</h4>Respiratory viral infections can cause significant morbidity and mortality in immunocompromised patients. Conventional tests routinely available at most institutions are limited by the number of detectable pathogens, by a poor sensitivity and/or a long turnaround time.<h4>Objectives</h4>To compare the performance of routine conventional testing with direct fluorescent antibody assays and viral culture to a customized TaqMan® array card (TAC) real-time PCR method, targeting 24  ...[more]

Similar Datasets

| S-EPMC7119654 | biostudies-literature
| S-EPMC5228222 | biostudies-literature
| S-EPMC3457462 | biostudies-literature
| S-EPMC7113746 | biostudies-literature
| S-EPMC7114243 | biostudies-literature
| S-EPMC3553916 | biostudies-literature
| S-EPMC5417650 | biostudies-literature
| S-EPMC6438039 | biostudies-literature
| S-EPMC4922116 | biostudies-literature
| S-EPMC6321855 | biostudies-literature