Aim

Continuous real-time echocardiographic monitoring is essential for guidance during ASD closure. However, transthoracic echocardiography (TTE) can only be implemented intermittently during fluoroscopy. We evaluate a novel approach to provide real-time imaging during the entire procedure.

Finding

We developed a custom-made TTE monitoring apparatus using artificial hand (AH-TTE) that enables real-time TTE images during atrial septal defect (ASD) closure. Thirty-two patients underwent successful device implantation using AH-TTE monitoring without complications. The median duration for real-time AH-TTE monitoring was 22?min and the median fluoroscopy time was 7.2?min. One case of pericardial effusion and one of transient bradycardia event due to air embolism was detected. All patients had uneventful recoveries.

Conclusions

Our simple and novel monitoring technique with AH-TTE provides TEE-like monitoring and may be a new alternative method for ASD closure. It gives real-time stable TTE images and minimizes radiation exposure for the interventional team during fluoroscopy.

SUBMITTER: Fu YC 

PROVIDER: S-EPMC7302396 | biostudies-literature | 2020 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Transthoracic echocardiography monitoring during ASD closure using an artificial hand system.

Fu Yun-Ching YC   Tsai Shen Kou SK   Jian Wen-Yen WY   Shyu Tsung-Cheng TC   Chuang Chieh-Mao CM   Hwang Betau B  

Cardiovascular ultrasound 20200617 1


<h4>Aim</h4>Continuous real-time echocardiographic monitoring is essential for guidance during ASD closure. However, transthoracic echocardiography (TTE) can only be implemented intermittently during fluoroscopy. We evaluate a novel approach to provide real-time imaging during the entire procedure.<h4>Finding</h4>We developed a custom-made TTE monitoring apparatus using artificial hand (AH-TTE) that enables real-time TTE images during atrial septal defect (ASD) closure. Thirty-two patients under  ...[more]

Similar Datasets

| S-EPMC4748720 | biostudies-literature
| S-EPMC4520740 | biostudies-literature
| S-EPMC6358410 | biostudies-literature
| S-EPMC2806252 | biostudies-literature
| S-EPMC5889411 | biostudies-literature
| S-EPMC8026547 | biostudies-literature
| S-EPMC5408533 | biostudies-literature
| S-EPMC6291087 | biostudies-literature
| S-EPMC6684740 | biostudies-literature
| S-EPMC2614958 | biostudies-literature