Unknown

Dataset Information

0

Loop-mediated isothermal amplification (LAMP) reaction as viable PCR substitute for diagnostic applications: a comparative analysis study of LAMP, conventional PCR, nested PCR (nPCR) and real-time PCR (qPCR) based on Entamoeba histolytica DNA derived from faecal sample.


ABSTRACT: BACKGROUND:This study reports the analytical sensitivity and specificity of a Loop-mediated isothermal amplification (LAMP) and compares its amplification performance with conventional PCR, nested PCR (nPCR) and real-time PCR (qPCR). All the assays demonstrated in this study were developed based on Serine-rich Entamoeba histolytica protein (SREHP) gene as study model. RESULTS:A set of SREHP gene specific LAMP primers were designed for the specific detection of Entamoeba histolytica. This set of primers recorded 100% specificity when it was evaluated against 3 medically important Entamoeba species and 75 other pathogenic microorganisms. These primers were later modified for conventional PCR, nPCR and qPCR applications. Besides, 3 different post-LAMP analyses including agarose gel electrophoresis, nucleic acid lateral flow immunoassay and calcein-manganese dye techniques were used to compare their limit of detection (LoD). One E. histolytica trophozoite was recorded as the LoD for all the 3 post-LAMP analysis methods when tested with E. histolytica DNA extracted from spiked stool samples. In contrast, none of the PCR method outperformed LAMP as both qPCR and nPCR recorded LoD of 100 trophozoites while the LoD of conventional PCR was 1000 trophozoites. CONCLUSIONS:The analytical sensitivity comparison among the conventional PCR, nPCR, qPCR and LAMP reveals that the LAMP outperformed the others in terms of LoD and amplification time. Hence, LAMP is a relevant alternative DNA-based amplification platform for sensitive and specific detection of pathogens.

SUBMITTER: Foo PC 

PROVIDER: S-EPMC7310076 | biostudies-literature | 2020 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Loop-mediated isothermal amplification (LAMP) reaction as viable PCR substitute for diagnostic applications: a comparative analysis study of LAMP, conventional PCR, nested PCR (nPCR) and real-time PCR (qPCR) based on Entamoeba histolytica DNA derived from faecal sample.

Foo Phiaw Chong PC   Nurul Najian A B AB   Muhamad Nuramin A NA   Ahamad Mariana M   Mohamed Maizan M   Yean Yean Chan C   Lim Boon Huat BH  

BMC biotechnology 20200622 1


<h4>Background</h4>This study reports the analytical sensitivity and specificity of a Loop-mediated isothermal amplification (LAMP) and compares its amplification performance with conventional PCR, nested PCR (nPCR) and real-time PCR (qPCR). All the assays demonstrated in this study were developed based on Serine-rich Entamoeba histolytica protein (SREHP) gene as study model.<h4>Results</h4>A set of SREHP gene specific LAMP primers were designed for the specific detection of Entamoeba histolytic  ...[more]

Similar Datasets

| S-EPMC6519685 | biostudies-literature
| S-EPMC5374617 | biostudies-literature
| S-EPMC1594701 | biostudies-literature
| S-EPMC1829108 | biostudies-literature
| S-EPMC4345085 | biostudies-literature
| S-EPMC2691116 | biostudies-literature
| S-EPMC1153781 | biostudies-literature
| S-EPMC1888694 | biostudies-literature
| PRJNA139909 | ENA
| PRJNA51433 | ENA