Web portal for analytical validation of MRM-MS assay abided with integrative multinational guidelines.


ABSTRACT: Multiple reaction monitoring-mass spectrometry became a mainstream method for quantitative proteomics, which made the validation of a method and the analyzed data important. In this portal for validation of the MRM-MS assay, we developed a website that automatically evaluates uploaded MRM-MS data, based on biomarker assay guidelines from the European Medicines Agency, the US Food & Drug Administration, and the Korea Food & Drug Administration. The portal reads a Skyline output file and produces the following results-calibration curve, specificity, sensitivity, carryover, precision, recovery, matrix effect, recovery, dilution integrity, stability, and QC-according to the standards of each independent agency. The final tables and figures that pertain to the 11 evaluation categories are displayed in an individual page. Spring boot was used as a framework for development of the webpage, which follows MVC Pattern. JSP, HTML, XML, and Java Script were used to develop the webpage. A server was composed of Apache Tomcat, MySQL. Input files were skyline-derived output files (csv file), and each files were organized by specific columns in order. SQL, JAVA were interworked to evaluate all the categories and show the results. Method Validation Portal can be accessed via any kind of explorer from https://pnbvalid.snu.ac.kr.

SUBMITTER: Kim J 

PROVIDER: S-EPMC7331696 | biostudies-literature | 2020 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Web portal for analytical validation of MRM-MS assay abided with integrative multinational guidelines.

Kim Jaenyeon J   Yeo Injoon I   Kim Hyunsoo H   Sohn Areum A   Kim Yoseop Y   Kim Youngsoo Y  

Scientific reports 20200702 1


Multiple reaction monitoring-mass spectrometry became a mainstream method for quantitative proteomics, which made the validation of a method and the analyzed data important. In this portal for validation of the MRM-MS assay, we developed a website that automatically evaluates uploaded MRM-MS data, based on biomarker assay guidelines from the European Medicines Agency, the US Food & Drug Administration, and the Korea Food & Drug Administration. The portal reads a Skyline output file and produces  ...[more]

Similar Datasets

| S-EPMC5570484 | biostudies-literature
| S-EPMC3572035 | biostudies-literature
| S-EPMC8035963 | biostudies-literature
| S-EPMC2688524 | biostudies-literature
| S-EPMC11002930 | biostudies-literature
| S-EPMC4492791 | biostudies-literature
| S-EPMC6386465 | biostudies-literature
| S-EPMC3331852 | biostudies-other
| S-EPMC8723902 | biostudies-literature
2024-10-18 | PXD056935 |