Cellular Force Nanoscopy with 50 nm Resolution Based on Integrin Molecular Tension Imaging and Localization.


ABSTRACT: Integrin-transmitted cellular forces have rich spatial dynamics and are vital to many cellular functions. To advance the sensitivity and spatial resolution of cellular force imaging, we developed a force-activatable emitter reporting single-molecular tension events and the associated cellular force nanoscopy (CFN). Immobilized on a surface, the emitters are initially dark (>99.8% quenched), providing a low fluorescence background despite the high coating density (>2000/?m2) required for sampling cellular force properly. The emitters fluoresce brightly once switched on by integrin tensions and can be switched off by photobleaching, enabling continuous real-time imaging of integrin molecular tensions in live cells. With multiple cycles of molecular tension imaging and localization, CFN reproduces cellular force images with 50 nm resolution. Applied to both migratory cells and stationary cells, CFN revealed ultranarrow distribution of integrin tensions at the cell leading edge, and showed that force distribution in focal adhesions (FAs) is off-centered and FA size-dependent.

SUBMITTER: Zhao Y 

PROVIDER: S-EPMC7337222 | biostudies-literature | 2020 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Cellular Force Nanoscopy with 50 nm Resolution Based on Integrin Molecular Tension Imaging and Localization.

Zhao Yuanchang Y   Pal Kaushik K   Tu Ying Y   Wang Xuefeng X  

Journal of the American Chemical Society 20200402 15


Integrin-transmitted cellular forces have rich spatial dynamics and are vital to many cellular functions. To advance the sensitivity and spatial resolution of cellular force imaging, we developed a force-activatable emitter reporting single-molecular tension events and the associated cellular force nanoscopy (CFN). Immobilized on a surface, the emitters are initially dark (>99.8% quenched), providing a low fluorescence background despite the high coating density (>2000/μm<sup>2</sup>) required f  ...[more]

Similar Datasets

| S-EPMC6613363 | biostudies-literature
| S-EPMC7610943 | biostudies-literature
| S-EPMC8595732 | biostudies-literature
| S-EPMC5390314 | biostudies-literature
| S-EPMC3271870 | biostudies-other
| S-EPMC3699760 | biostudies-literature
| S-EPMC6549505 | biostudies-literature
| S-EPMC11345772 | biostudies-literature
| S-EPMC10980004 | biostudies-literature
| S-EPMC4595625 | biostudies-literature