Unknown

Dataset Information

0

Electrical antimicrobial susceptibility testing based on aptamer-functionalized capacitance sensor array for clinical isolates.


ABSTRACT: To prescribe effective antibiotics to patients with bacterial infections in a timely manner and to avoid the misuse of antibiotics, a rapid antimicrobial susceptibility test (AST) is essential. However, conventional AST methods require more than 16 h to provide results; thus, we developed an electrical AST (e-AST) system, which provides results within 6 h. The proposed e-AST is based on an array of 60 aptamer-functionalized capacitance sensors that are comparable to currently available AST panels and a pattern-matching algorithm. The performance of the e-AST was evaluated in comparison with that of broth microdilution as the reference test for clinical strains isolated from septic patients. A total of 4,554 tests using e-AST showed a categorical agreement of 97% with a minor error of 2.2%, major error of 0.38%, and very major error of 0.38%. We expect that the proposed e-AST could potentially aid antimicrobial stewardship efforts and lead to improved patient outcomes.

SUBMITTER: Lee KS 

PROVIDER: S-EPMC7426404 | biostudies-literature | 2020 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Electrical antimicrobial susceptibility testing based on aptamer-functionalized capacitance sensor array for clinical isolates.

Lee Kyo-Seok KS   Lee Sun-Mi SM   Oh Jeseung J   Park In Ho IH   Song Jun Ho JH   Han Myeonggil M   Yong Dongeun D   Lim Kook Jin KJ   Shin Jeon-Soo JS   Yoo Kyung-Hwa KH  

Scientific reports 20200813 1


To prescribe effective antibiotics to patients with bacterial infections in a timely manner and to avoid the misuse of antibiotics, a rapid antimicrobial susceptibility test (AST) is essential. However, conventional AST methods require more than 16 h to provide results; thus, we developed an electrical AST (e-AST) system, which provides results within 6 h. The proposed e-AST is based on an array of 60 aptamer-functionalized capacitance sensors that are comparable to currently available AST panel  ...[more]

Similar Datasets

| S-EPMC2446839 | biostudies-literature
| S-EPMC8601779 | biostudies-literature
| S-EPMC4457143 | biostudies-literature
| S-EPMC5695042 | biostudies-literature
| S-EPMC8080699 | biostudies-literature
| S-EPMC3498495 | biostudies-literature
| S-EPMC8764967 | biostudies-literature
| S-EPMC3697729 | biostudies-literature
| S-EPMC7358464 | biostudies-literature
| S-EPMC7138758 | biostudies-literature