Unknown

Dataset Information

0

Repeatability of Cardiac Magnetic Resonance Radiomics: A Multi-Centre Multi-Vendor Test-Retest Study.


ABSTRACT: Aims: To evaluate the repeatability of cardiac magnetic resonance (CMR) radiomics features on test-retest scanning using a multi-centre multi-vendor dataset with a varied case-mix. Methods and Results: The sample included 54 test-retest studies from the VOLUMES resource (thevolumesresource.com). Images were segmented according to a pre-defined protocol to select three regions of interest (ROI) in end-diastole and end-systole: right ventricle, left ventricle (LV), and LV myocardium. We extracted radiomics shape features from all three ROIs and, additionally, first-order and texture features from the LV myocardium. Overall, 280 features were derived per study. For each feature, we calculated intra-class correlation coefficient (ICC), within-subject coefficient of variation, and mean relative difference. We ranked robustness of features according to mean ICC stratified by feature category, ROI, and cardiac phase, demonstrating a wide range of repeatability. There were features with good and excellent repeatability (ICC ? 0.75) within all feature categories and ROIs. A high proportion of first-order and texture features had excellent repeatability (ICC ? 0.90), however, these categories also contained features with the poorest repeatability (ICC < 0.50). Conclusion: CMR radiomic features have a wide range of repeatability. This paper is intended as a reference for future researchers to guide selection of the most robust features for clinical CMR radiomics models. Further work in larger and richer datasets is needed to further define the technical performance and clinical utility of CMR radiomics.

SUBMITTER: Raisi-Estabragh Z 

PROVIDER: S-EPMC7738466 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Repeatability of Cardiac Magnetic Resonance Radiomics: A Multi-Centre Multi-Vendor Test-Retest Study.

Raisi-Estabragh Zahra Z   Gkontra Polyxeni P   Jaggi Akshay A   Cooper Jackie J   Augusto João J   Bhuva Anish N AN   Davies Rhodri H RH   Manisty Charlotte H CH   Moon James C JC   Munroe Patricia B PB   Harvey Nicholas C NC   Lekadir Karim K   Petersen Steffen E SE  

Frontiers in cardiovascular medicine 20201202


<b>Aims:</b> To evaluate the repeatability of cardiac magnetic resonance (CMR) radiomics features on test-retest scanning using a multi-centre multi-vendor dataset with a varied case-mix. <b>Methods and Results:</b> The sample included 54 test-retest studies from the VOLUMES resource (thevolumesresource.com). Images were segmented according to a pre-defined protocol to select three regions of interest (ROI) in end-diastole and end-systole: right ventricle, left ventricle (LV), and LV myocardium.  ...[more]

Similar Datasets

| S-EPMC6423042 | biostudies-literature
| S-EPMC9639305 | biostudies-literature
| S-EPMC4623457 | biostudies-literature
| S-EPMC10334409 | biostudies-literature
| S-EPMC8833034 | biostudies-literature
| S-EPMC4444127 | biostudies-literature
| S-EPMC7891585 | biostudies-literature
| S-EPMC7082724 | biostudies-literature
| S-EPMC10141060 | biostudies-literature
| S-EPMC6175053 | biostudies-literature