In-situ monitoring for liquid metal jetting using a millimeter-wave impedance diagnostic.


ABSTRACT: This article presents a millimeter-wave diagnostic for the in-situ monitoring of liquid metal jetting additive manufacturing systems. The diagnostic leverages a T-junction waveguide device to monitor impedance changes due to jetted metal droplets in real time. An analytical formulation for the time-domain T-junction operation is presented and supported with a quasi-static full-wave electromagnetic simulation model. The approach is evaluated experimentally with metallic spheres of known diameters ranging from 0.79 to 3.18 mm. It is then demonstrated in a custom drop-on-demand liquid metal jetting system where effective droplet diameters ranging from 0.8 to 1.6 mm are detected. Experimental results demonstrate that this approach can provide information about droplet size, timing, and motion by monitoring a single parameter, the reflection coefficient amplitude at the input port. These results show the promise of the impedance diagnostic as a reliable in-situ characterization method for metal droplets in an advanced manufacturing system.

SUBMITTER: Chang T 

PROVIDER: S-EPMC7749153 | biostudies-literature | 2020 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

In-situ monitoring for liquid metal jetting using a millimeter-wave impedance diagnostic.

Chang Tammy T   Mukherjee Saptarshi S   Watkins Nicholas N NN   Stobbe David M DM   Mays Owen O   Baluyot Emer V EV   Pascall Andrew J AJ   Tringe Joseph W JW  

Scientific reports 20201218 1


This article presents a millimeter-wave diagnostic for the in-situ monitoring of liquid metal jetting additive manufacturing systems. The diagnostic leverages a T-junction waveguide device to monitor impedance changes due to jetted metal droplets in real time. An analytical formulation for the time-domain T-junction operation is presented and supported with a quasi-static full-wave electromagnetic simulation model. The approach is evaluated experimentally with metallic spheres of known diameters  ...[more]

Similar Datasets

| S-EPMC9313324 | biostudies-literature
| S-EPMC6170430 | biostudies-literature
| S-EPMC8759749 | biostudies-literature
| S-EPMC4817506 | biostudies-other
| S-EPMC7358722 | biostudies-literature
| S-EPMC9836044 | biostudies-literature
| S-EPMC9586033 | biostudies-literature
| S-EPMC4883316 | biostudies-literature
| S-EPMC5521226 | biostudies-literature
| S-EPMC3686354 | biostudies-literature