Development of an Interdigitated Electrode-Based Disposable Enzyme Sensor Strip for Glycated Albumin Measurement.


ABSTRACT: Glycated albumin (GA) is an important glycemic control marker for diabetes mellitus. This study aimed to develop a highly sensitive disposable enzyme sensor strip for GA measurement by using an interdigitated electrode (IDE) as an electrode platform. The superior characteristics of IDE were demonstrated using one microelectrode of the IDE pair as the working electrode (WE) and the other as the counter electrode, and by measuring ferrocyanide/ferricyanide redox couple. The oxidation current was immediately reached at the steady state when the oxidation potential was applied to the WE. Then, an IDE enzyme sensor strip for GA measurement was prepared. The measurement of fructosyl lysine, the protease digestion product of GA, exhibited a high, steady current immediately after potential application, revealing the highly reproducible measurement. The sensitivity (2.8 nA µM-1) and the limit of detection (1.2 µM) obtained with IDE enzyme sensor strip were superior compared with our previously reported sensor using screen printed electrode. Two GA samples, 15 or 30% GA, corresponding to healthy and diabetic levels, respectively, were measured after protease digestion with high resolution. This study demonstrated that the application of an IDE will realize the development of highly sensitive disposable-type amperometric enzyme sensors with high reproducibility.

SUBMITTER: Hatada M 

PROVIDER: S-EPMC7866809 | biostudies-literature | 2021 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Development of an Interdigitated Electrode-Based Disposable Enzyme Sensor Strip for Glycated Albumin Measurement.

Hatada Mika M   Loew Noya N   Okuda-Shimazaki Junko J   Khanwalker Mukund M   Tsugawa Wakako W   Mulchandani Ashok A   Sode Koji K  

Molecules (Basel, Switzerland) 20210131 3


Glycated albumin (GA) is an important glycemic control marker for diabetes mellitus. This study aimed to develop a highly sensitive disposable enzyme sensor strip for GA measurement by using an interdigitated electrode (IDE) as an electrode platform. The superior characteristics of IDE were demonstrated using one microelectrode of the IDE pair as the working electrode (WE) and the other as the counter electrode, and by measuring ferrocyanide/ferricyanide redox couple. The oxidation current was i  ...[more]

Similar Datasets

| S-EPMC8168339 | biostudies-literature
| S-EPMC8002523 | biostudies-literature
| S-EPMC6314057 | biostudies-literature
| S-EPMC6749378 | biostudies-literature
| S-EPMC6571116 | biostudies-literature
| S-EPMC7506670 | biostudies-literature
| S-EPMC8161293 | biostudies-literature
| S-EPMC7329883 | biostudies-literature
| S-EPMC6839135 | biostudies-literature
2023-07-20 | PXD040028 | Pride