Origami paper analytical assay based on metal complex sensor for rapid determination of blood cyanide concentration in fire survivors.


ABSTRACT: Cyanide-based blood poisoning can seriously damage fire victims and cause death if not detected quickly. Previous conventional methods require laboratory equipment, which are expensive and increase the duration of the analysis. Here, a simple origami based microfluidic device was introduced for point of need detection of blood cyanide concentration in people involved in fire. The device is made of four layers of paper. Each layer was in the size of 1?×?1 cm folded on each other. In this work, the blood sample was acidified by trichloroacetic acid to separate cyanide from methaemoglobin in the form of HCN gas. The produced gas released into borate buffer to recover free cyanide ions which interacted with the Pt complex ([Pt(p-MeC6H4)2(phen)]) used as a receptor in this study. Optimized conditions were applied to have a suitable interaction causing the color of the receptor to change from yellow to colorless. The color changes were recorded by a smartphone, and the sensor response was calculated by the routine image analysis software. The assay was capable of determining cyanide ions at different concentrations in the range of 1.0 to 100.0 µmol L-1. The detection limit of these determination was equal to 0.4 µmol L-1. The assay responses were not affected by the interfering species. As a practical analysis, the proposed sensor was applied to determine cyanide ions in the blood sample of 20 studied fire survivors and 10 controls with high accuracy.

SUBMITTER: Sheini A 

PROVIDER: S-EPMC7876125 | biostudies-literature | 2021 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Origami paper analytical assay based on metal complex sensor for rapid determination of blood cyanide concentration in fire survivors.

Sheini Azarmidokht A   Aseman Marzieh Dadkhah MD   Bordbar Mohammad Mahdi MM  

Scientific reports 20210210 1


Cyanide-based blood poisoning can seriously damage fire victims and cause death if not detected quickly. Previous conventional methods require laboratory equipment, which are expensive and increase the duration of the analysis. Here, a simple origami based microfluidic device was introduced for point of need detection of blood cyanide concentration in people involved in fire. The device is made of four layers of paper. Each layer was in the size of 1 × 1 cm folded on each other. In this work, th  ...[more]

Similar Datasets

| S-EPMC3852662 | biostudies-literature
| S-EPMC3486962 | biostudies-literature
| S-EPMC6566168 | biostudies-literature
| S-EPMC8777769 | biostudies-literature
| S-EPMC3931572 | biostudies-literature
| S-EPMC7560735 | biostudies-literature
| S-EPMC4062392 | biostudies-literature
| S-EPMC7916752 | biostudies-literature
| S-EPMC9030608 | biostudies-literature