Unknown

Dataset Information

0

An All-in-One Solid State Thin-Layer Potentiometric Sensor and Biosensor Based on Three-Dimensional Origami Paper Microfluidics.


ABSTRACT: An origami three-dimensional design of a paper-based potentiometric sensor is described. In its simplest form, this electrochemical paper-based analytical device (ePAD) is made from three small parts of the paper. Paper layers are folded on each other for the integration of a solid contact ion selective electrode (here a carbon-paste composite electrode) and a solid-state pseudo-reference electrode (here writing pencil 6B on the paper), which are in contact with a hydrophilic channel fabricated on the middle part (third part) of the paper. In this case, the pseudo-reference and working electrodes are connected to the two sides of the hydrophilic channel and hence the distance between them is as low as the width of paper. The unmodified carbon paste electrode (UCPE) and modification with the crown ether benzo15-crown-5 (B15C5) represented a very high sensitivity to Cu (II) and Cd2+ ions, respectively. The sensor responded to H2O2 using MnO2-doped carbon paste electrode (CPE). Furthermore, a biosensor was achieved by the addition of glucose oxidase to the MnO2-doped CPE and hence made it selective to glucose with ultra-sensitivity. In addition to very high sensitivity, our device benefits from consuming a very low volume of sample (10.0 µL) and automatic sampling without need for sampling devices.

SUBMITTER: Pesaran S 

PROVIDER: S-EPMC7916752 | biostudies-literature | 2021 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

An All-in-One Solid State Thin-Layer Potentiometric Sensor and Biosensor Based on Three-Dimensional Origami Paper Microfluidics.

Pesaran Shiva S   Rafatmah Elmira E   Hemmateenejad Bahram B  

Biosensors 20210210 2


An origami three-dimensional design of a paper-based potentiometric sensor is described. In its simplest form, this electrochemical paper-based analytical device (ePAD) is made from three small parts of the paper. Paper layers are folded on each other for the integration of a solid contact ion selective electrode (here a carbon-paste composite electrode) and a solid-state pseudo-reference electrode (here writing pencil 6B on the paper), which are in contact with a hydrophilic channel fabricated  ...[more]

Similar Datasets

| S-EPMC9599061 | biostudies-literature
| S-EPMC4892122 | biostudies-literature
| S-EPMC8402598 | biostudies-literature
| S-EPMC8434286 | biostudies-literature
| S-EPMC7560735 | biostudies-literature
| S-EPMC8125673 | biostudies-literature
| S-EPMC4062392 | biostudies-literature
| S-EPMC10042807 | biostudies-literature
| S-EPMC2818357 | biostudies-literature
| S-EPMC7591913 | biostudies-literature