Unknown

Dataset Information

0

Modelling and parameter optimisation for performance evaluation of sequencing batch reactor for treating hospital wastewater.


ABSTRACT: Hospital wastewater treatment is gaining attention in recent studies due to its complex nature. The performance of the sequencing batch reactor coupled with tube-settler was investigated for hospital wastewater treatment. The performance was evaluated regarding removing organic matter and nutrients (nitrate and phosphate). The phosphate was removed in the sequencing batch reactor and its associated tube-settler with a 60% removal efficiency margin. Nitrification was observed in sequencing batch reactor and tube-settler, but denitrification could not be achieved. The nitrification-denitrification process was not completed during the process. The current work's main aim was to understand and optimise the operational parameters involved in the performance of the sequencing batch reactor. The operational parameters were optimised using Design expert software, and Response Surface Methodology involved a four-factor and five-level central composite design. The percentage removal of chemical oxygen demand, nitrate, and phosphate was selected to be observed during this study.

Graphical abstract

Supplementary information

The online version contains supplementary material available at 10.1007/s13399-022-03406-z.

SUBMITTER: Khan NA 

PROVIDER: S-EPMC9628615 | biostudies-literature | 2022 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Modelling and parameter optimisation for performance evaluation of sequencing batch reactor for treating hospital wastewater.

Khan Nadeem A NA   Morabet Rachida El RE   Khan Roohul Abad RA   Alsubih Majed M   Gaurav Gajendra Kumar GK   Klemeš Jiří Jaromír JJ   Thakur Amit K AK  

Biomass conversion and biorefinery 20221101


Hospital wastewater treatment is gaining attention in recent studies due to its complex nature. The performance of the sequencing batch reactor coupled with tube-settler was investigated for hospital wastewater treatment. The performance was evaluated regarding removing organic matter and nutrients (nitrate and phosphate). The phosphate was removed in the sequencing batch reactor and its associated tube-settler with a 60% removal efficiency margin. Nitrification was observed in sequencing batch  ...[more]

Similar Datasets

| S-EPMC8637490 | biostudies-literature
| S-EPMC10405192 | biostudies-literature
| S-EPMC9105176 | biostudies-literature
| S-EPMC4843016 | biostudies-literature
| S-EPMC10734506 | biostudies-literature
| S-EPMC9518340 | biostudies-literature
| S-EPMC5464570 | biostudies-literature
| S-EPMC6141387 | biostudies-literature
| S-EPMC7236998 | biostudies-literature
| S-EPMC3131513 | biostudies-literature