Self-Test Procedures for Gas Sensors Embedded in Microreactor Systems.


ABSTRACT: Metal oxide (MOX) gas sensors sensitively respond to a wide variety of combustible, explosive and poisonous gases. However, due to the lack of a built-in self-test capability, MOX gas sensors have not yet been able to penetrate safety-critical applications. In the present work we report on gas sensing experiments performed on MOX gas sensors embedded in ceramic micro-reaction chambers. With the help of an external micro-pump, such systems can be operated in a periodic manner alternating between flow and no-flow conditions, thus allowing repetitive measurements of the sensor resistances under clean air, R 0 , and under gas exposure, R g a s , to be obtained, even under field conditions. With these pairs of resistance values, eventual drifts in the sensor baseline resistance can be detected and drift-corrected values of the relative resistance response R e s p = ( R 0 - R g a s ) / R 0 can be determined. Residual poisoning-induced changes in the relative resistance response can be detected by reference to humidity measurements taken with room-temperature-operated capacitive humidity sensors which are insensitive to the poisoning processes operative on heated MOX gas sensors.

SUBMITTER: Helwig A 

PROVIDER: S-EPMC5855490 | biostudies-other | 2018 Feb

REPOSITORIES: biostudies-other

altmetric image

Publications

Self-Test Procedures for Gas Sensors Embedded in Microreactor Systems.

Helwig Andreas A   Hackner Angelika A   Müller Gerhard G   Zappa Dario D   Sberveglieri Giorgio G  

Sensors (Basel, Switzerland) 20180203 2


Metal oxide (MOX) gas sensors sensitively respond to a wide variety of combustible, explosive and poisonous gases. However, due to the lack of a built-in self-test capability, MOX gas sensors have not yet been able to penetrate safety-critical applications. In the present work we report on gas sensing experiments performed on MOX gas sensors embedded in ceramic micro-reaction chambers. With the help of an external micro-pump, such systems can be operated in a periodic manner alternating between  ...[more]

Similar Datasets

| S-EPMC9728961 | biostudies-literature
| S-EPMC5128020 | biostudies-literature
| S-EPMC3170200 | biostudies-other
| S-EPMC6266552 | biostudies-literature
| S-EPMC10134802 | biostudies-literature
| S-EPMC9898262 | biostudies-literature
| S-EPMC6539445 | biostudies-other
| S-EPMC10192647 | biostudies-literature
| S-EPMC6387115 | biostudies-literature
| S-EPMC9417045 | biostudies-literature