Sampling and homogenization of nanoliter tissue with a nanosecond infrared laser (NIRL) for mass spectrometric proteomics


ABSTRACT: It was recently shown that ultrashort pulse infrared (IR) lasers, operating at the wavelength of the OH vibration stretching band of water, are highly efficient at softly sampling and homogenizing biological tissue. We utilized a nanosecond infrared laser (NIRL) for tissue sampling and homogenization with subsequent LC-MS/MS analysis for mass spectrometric proteomics. Sampling was performed with murine spleen and colon tissue with an ablation volume of 1.1 x 1.1 x0.4 mm³ (approx. 0.5 µl), determined with optical coherence tomography (OCT). The identified proteins of both tissues contained tissue type specific proteins correlating with the corresponding lists of the Human Protein Atlas. The results demonstrate that tissue sampling and homogenization of small tissue volumes less than 1 µL for subsequent mass spectrometric proteomics is feasible with a NIRL and therefore is an alternative towards sampling of tissue sections with laser capture microdissection (LCM).

INSTRUMENT(S): Q Exactive

ORGANISM(S): Mus Musculus (mouse)

TISSUE(S): Spleen, Colon

SUBMITTER: Manuela Moritz  

LAB HEAD: Prof. Dr. Hartmut Schlüter

PROVIDER: PXD027700 | Pride | 2022-02-17

REPOSITORIES: Pride

Dataset's files

Source:
Action DRS
HV_200313_Laser_Colon3KD.mzML Mzml
HV_200313_Laser_Colon4KD.mzML Mzml
HV_200313_Laser_Colon5KD.mzML Mzml
HV_200313_Laser_Spleen2SWT_20200315194013.mzML Mzml
HV_200313_Laser_Spleen5SWT_20200315121909.mzML Mzml
Items per page:
1 - 5 of 8
altmetric image

Publications

Tissue Sampling and Homogenization in the Sub-Microliter Scale with a Nanosecond Infrared Laser (NIRL) for Mass Spectrometric Proteomics.

Hahn Jan J   Moritz Manuela M   Voß Hannah H   Pelczar Penelope P   Huber Samuel S   Schlüter Hartmut H  

International journal of molecular sciences 20211007 19


It was recently shown that ultrashort pulse infrared (IR) lasers, operating at the wavelength of the OH vibration stretching band of water, are highly efficient for sampling and homogenizing biological tissue. In this study we utilized a tunable nanosecond infrared laser (NIRL) for tissue sampling and homogenization with subsequent liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis for mass spectrometric proteomics. For the first time, laser sampling was performed with murine spl  ...[more]

Similar Datasets

2024-01-26 | PXD043011 | Pride
2022-06-22 | PXD033584 | Pride
2014-11-01 | E-GEOD-45125 | biostudies-arrayexpress
2018-09-24 | PXD009744 | Pride
2022-05-19 | PXD028407 | Pride
2021-04-27 | PXD016213 | Pride
2021-03-22 | PXD024356 | Pride
2010-05-25 | E-GEOD-8942 | biostudies-arrayexpress
2016-01-25 | PXD003434 | Pride
2010-05-05 | E-GEOD-15260 | biostudies-arrayexpress