Unknown,Transcriptomics,Genomics,Proteomics

Dataset Information

0

Porcine gene response following incision with energized devices


ABSTRACT: This study compares the gene expression changes in Sus scrofa in response to two different methods for abdominal surgical incisions ; electrosurgery and harmonic blade. As the use of laparoscopic surgery has become more widespread in recent years, the need has increased for minimally-invasive surgical devices that effectively cut and coagulate tissue with reduced tissue trauma. Although electrosurgery (ES) has been used for many generations, newly-developed ultrasonic devices (HARMONIC® Blade, HB) have been shown at a macroscopic level to offer better coagulation with less thermally-induced tissue damage. We sought to understand the differences between ES and HB at a microscopic level by comparing mRNA transcript and protein responses at the 3-day timepoint to incisions made by the devices in subcutaneous fat tissue in a porcine model This study used four 4-cm midline caudal abdominal incisions created with the test devices in two female pigs. The test devices were monopolar electrosurgery and Harmonic blade. Each animal had two Harmonic Blade incisions and two Electrosurgery incisions for a total of 8 incisions

ORGANISM(S): Sus scrofa

SUBMITTER: Bindu Nanduri 

PROVIDER: E-GEOD-47710 | biostudies-arrayexpress |

REPOSITORIES: biostudies-arrayexpress

altmetric image

Publications

Ultrasonic incisions produce less inflammatory mediator response during early healing than electrosurgical incisions.

Nanduri Bindu B   Pendarvis Ken K   Shack Leslie A LA   Kumar Ranjit R   Clymer Jeffrey W JW   Korvick Donna L DL   Burgess Shane C SC  

PloS one 20130918 9


As the use of laparoscopic surgery has become more widespread in recent years, the need has increased for minimally-invasive surgical devices that effectively cut and coagulate tissue with reduced tissue trauma. Although electrosurgery (ES) has been used for many generations, newly-developed ultrasonic devices (HARMONIC® Blade, HB) have been shown at a macroscopic level to offer better coagulation with less thermally-induced tissue damage. We sought to understand the differences between ES and H  ...[more]

Similar Datasets

2013-12-15 | GSE47710 | GEO
2014-04-15 | PXD000038 | Pride
2024-10-17 | PXD054629 | Pride
2023-06-13 | PXD039845 | Pride
2024-01-20 | PXD028461 | Pride
2011-09-29 | E-GEOD-32494 | biostudies-arrayexpress
2011-05-03 | E-GEOD-28996 | biostudies-arrayexpress
2014-06-30 | E-MTAB-1158 | biostudies-arrayexpress
2012-10-02 | E-GEOD-33110 | biostudies-arrayexpress
2014-04-08 | E-GEOD-54356 | biostudies-arrayexpress