Low-Power AlGaN/GaN Triangular Microcantilever for Air Flow Detection.


ABSTRACT: This paper investigates an AlGaN/GaN triangular microcantilever with a heated apex for airflow detection utilizing a very simple two-terminal sensor configuration. Thermal microscope images were used to verify that the apex region of the microcantilever reached significantly higher temperatures than other parts under applied voltage bias. The sensor response was found to vary linearly with airflow rate when tested over a range of airflow varying from 16 to 2000 sccm. The noise-limited flow volume measurement yielded ~4 sccm resolution, while the velocity resolution was found to be 0.241 cm/s, which is one of the best reported so far for thermal sensors. The sensor was able to operate at a very low power consumption level of ~5 mW, which is one of the lowest reported for these types of sensors. The intrinsic response time of the sensor was estimated to be on the order of a few ms, limited by its thermal properties. Overall, the microcantilever sensor, with its simple geometry and measurement configurations, was found to exhibit attractive performance metrics useful for various sensing applications.

SUBMITTER: Uppalapati B 

PROVIDER: S-EPMC10490568 | biostudies-literature | 2023 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Low-Power AlGaN/GaN Triangular Microcantilever for Air Flow Detection.

Uppalapati Balaadithya B   Gajula Durga D   Bava Manav M   Muthusamy Lavanya L   Koley Goutam G  

Sensors (Basel, Switzerland) 20230828 17


This paper investigates an AlGaN/GaN triangular microcantilever with a heated apex for airflow detection utilizing a very simple two-terminal sensor configuration. Thermal microscope images were used to verify that the apex region of the microcantilever reached significantly higher temperatures than other parts under applied voltage bias. The sensor response was found to vary linearly with airflow rate when tested over a range of airflow varying from 16 to 2000 sccm. The noise-limited flow volum  ...[more]

Similar Datasets

| S-EPMC8433396 | biostudies-literature
| S-EPMC5527108 | biostudies-literature
| S-EPMC6747841 | biostudies-literature
| S-EPMC6874540 | biostudies-literature
| S-EPMC7508848 | biostudies-literature
| S-EPMC6187712 | biostudies-literature
| S-EPMC4570328 | biostudies-literature
| S-EPMC7560388 | biostudies-literature
| S-EPMC10654525 | biostudies-literature
| S-EPMC7570367 | biostudies-literature