Multiplex STR amplification sensitivity in a silicon microchip.


ABSTRACT: The demand for solutions to perform forensic DNA profiling outside of centralized laboratories is increasing. We here demonstrate highly sensitive STR amplification using a silicon micro-PCR (µPCR) chip. Exploiting industry-standard semiconductor manufacturing processes, a device was fabricated that features a small form factor thanks to an integrated heating element covering three parallel micro-reactors with a reaction volume of 0.5?µl each. Diluted reference DNA samples (1?ng-31?pg) were amplified on the µPCR chip using the forensically validated AmpFISTR Identifier Plus kit, followed by conventional capillary electrophoresis. Complete STR profiles were generated with input DNA quantities down to 62?pg. Occasional allelic dropouts were observed from 31?pg downward. On-chip STR profiles were compared with those of identical samples amplified using a conventional thermal cycler for direct comparison of amplification sensitivity in a forensic setting. The observed sensitivity was in line with kit specifications for both µPCR and conventional PCR. Finally, a rapid amplification protocol was developed. Complete STR profiles could be generated in less than 17?minutes from as little as 125?pg template DNA. Together, our results are an important step towards the development of commercial, mass-produced, relatively cheap, handheld devices for on-site testing in forensic DNA analysis.

SUBMITTER: Cornelis S 

PROVIDER: S-EPMC6026139 | biostudies-literature | 2018 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications


The demand for solutions to perform forensic DNA profiling outside of centralized laboratories is increasing. We here demonstrate highly sensitive STR amplification using a silicon micro-PCR (µPCR) chip. Exploiting industry-standard semiconductor manufacturing processes, a device was fabricated that features a small form factor thanks to an integrated heating element covering three parallel micro-reactors with a reaction volume of 0.5 µl each. Diluted reference DNA samples (1 ng-31 pg) were ampl  ...[more]

Similar Datasets

| S-EPMC8007628 | biostudies-literature
| S-EPMC7230633 | biostudies-literature
| S-EPMC4389811 | biostudies-other
| S-EPMC6051632 | biostudies-literature
| S-EPMC6517373 | biostudies-literature
| S-EPMC2990737 | biostudies-literature
| S-EPMC8625634 | biostudies-literature
| S-EPMC3494155 | biostudies-literature
| S-EPMC5446791 | biostudies-literature
| S-EPMC11217933 | biostudies-literature