A head-to-head comparison of personal and professional continuous glucose monitoring systems in people with type 1 diabetes: Hypoglycaemia remains the weak spot.


ABSTRACT: To compare the performance of a professional continuous glucose monitoring (proCGM) and a personal continuous glucose monitoring (persCGM) system worn in parallel under standardized conditions in individuals with type 1 diabetes (T1D), two CGM systems (iPro2 - proCGM; Minimed 640G - persCGM) worn in parallel using the same sensor (Enlite 2) were compared. Ten people with T1D were included in this single-centre, open-label study in which CGM performance was evaluated. The study consisted of a 24-hours inpatient phase (meals, exercise, glycaemic challenges) and a 4-day home phase. Analyses included fulfilment of ISO 15197:2013 criteria, mean absolute relative difference (MARD), Parkes Error Grid and Bland-Altman plots. During the inpatient stay, ISO 15197:2013 criteria fulfilment was 58.4% (proCGM) and 57.8% (persCGM). At home, the systems met ISO 15197:2013 criteria by 66.5% (proCGM) and 65.3% (persCGM). No difference of MARD in inpatient phase (19.1 ±?16.7% vs. 19.0 ±?19.6; P = 0.83) and home phase (18.6 ±?26.8% vs. 17.4 ±?21.3%, P = 0.87) was observed. All sensors performed less accurately during hypoglycaemia. ProCGM and persCGM showed similar performance during daytime and night-time for the inpatient and the home phase. However, sensor performance was reduced during hypoglycaemia for both systems.

SUBMITTER: Moser O 

PROVIDER: S-EPMC6590188 | biostudies-literature | 2019 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

A head-to-head comparison of personal and professional continuous glucose monitoring systems in people with type 1 diabetes: Hypoglycaemia remains the weak spot.

Moser Othmar O   Pandis Marlene M   Aberer Felix F   Kojzar Harald H   Hochfellner Daniel D   Elsayed Hesham H   Motschnig Melanie M   Augustin Thomas T   Kreuzer Philipp P   Pieber Thomas R TR   Sourij Harald H   Mader Julia K JK  

Diabetes, obesity & metabolism 20181225 4


To compare the performance of a professional continuous glucose monitoring (proCGM) and a personal continuous glucose monitoring (persCGM) system worn in parallel under standardized conditions in individuals with type 1 diabetes (T1D), two CGM systems (iPro2 - proCGM; Minimed 640G - persCGM) worn in parallel using the same sensor (Enlite 2) were compared. Ten people with T1D were included in this single-centre, open-label study in which CGM performance was evaluated. The study consisted of a 24-  ...[more]

Similar Datasets

| S-EPMC5888121 | biostudies-literature
| S-EPMC10699474 | biostudies-literature
| 71713 | ecrin-mdr-crc
| S-EPMC10562688 | biostudies-literature
| S-EPMC9092280 | biostudies-literature
| S-EPMC6848334 | biostudies-literature
| S-EPMC2997158 | biostudies-literature
| S-EPMC4409843 | biostudies-literature
| S-EPMC6551983 | biostudies-literature
| S-EPMC7956406 | biostudies-literature